View all text of Subpart 160.276 [§ 160.276-1 - § 160.276-25]

§ 160.276-13 - Approval inspections and tests.

(a) Each PFD must be certified by a recognized laboratory as meeting the requirements of ANSI/CAN/UL 12402-5 (incorporated by reference, see § 160.276-5) for an inflatable Level 50 or Level 70 PFD. Approval tests specified in ANSI/CAN/UL 12402-5 must be conducted or supervised by a recognized laboratory using PFDs constructed in accordance with the plans and specifications submitted with the application for approval.

(b) Each PFD design must be visually examined for compliance with the construction and performance requirements of this subpart and ANSI/CAN/UL 12402-5 (incorporated by reference, see § 160.276-5).

(c) The Commandant may prescribe additional tests for approval of novel or unique designs.