- Table 3 to Subpart HHH of Part 62—Operating Parameters To Be Monitored and Minimum Measurement and Recording Frequencies
Operating
parameters to be monitored | Minimum frequency | HMIWI | Data measurement | Data recording | HMIWI with combustion control only | HMIWI with dry scrubber followed by FF | HMIWI with wet scrubber | HMIWI with dry scrubber followed by FF and wet scrubber | HMIWI with SNCR system | Maximum operating parameters: | Maximum charge rate | Once per charge | Once per charge | ✓ | ✓ | ✓ | ✓ | ✓ | Maximum FF inlet temperature | Continuous | Once per minute | ✓ | ✓ | Maximum flue gas temperature | Continuous | Once per minute | ✓ | ✓ | Minimum operating parameters: | Minimum secondary chamber temperature | Continuous | Once per minute | ✓ | ✓ | ✓ | ✓ | ✓ | Minimum dioxin/furan sorbent flow rate | Hourly | Once per hour | ✓ | ✓ | Minimum HCl sorbent flow rate | Hourly | Once per hour | ✓ | ✓ | Minimum mercury (Hg) sorbent flow rate | Hourly | Once per hour | ✓ | ✓ | Minimum pressure drop across the wet scrubber or minimum horsepower or amperage to wet scrubber | Continuous | Once per minute | ✓ | ✓ | Minimum scrubber liquor flow rate | Continuous | Once per minute | ✓ | ✓ | Minimum scrubber liquor pH | Continuous | Once per minute | ✓ | ✓ | Minimum reagent flow rate | Hourly | Once per hour | ✓ |
---|