Appendix D - Appendix D to Part 61—Methods for Estimating Radionuclide Emissions

1. Purpose and Background

Facility owners or operators may estimate radionuclide emissions to the atmosphere for dose calculations instead of measuring emissions. Particulate emissions from mill tailings piles should be estimated using the procedures listed in reference re #2. All other emissions may be estimated by using the “Procedures” listed below, or using the method described in reference #1.

2. Procedure

To estimate emissions to the atmosphere:

(a) Determine the amount (in curies) used at facilities for the period under consideration. Radioactive materials in sealed packages that remain unopened, and have not leaked during the assessment period should not be included in the calculation.

(b) Multiply the amount used by the following factors which depend on the physical state of the radionuclide. They are:

(i) 1 for gases;

(ii) 10−3 for liquids or particulate solids; and

(iii) 10−6 for solids.

If any nuclide is heated to a temperature of 100 degrees Celsius or more, boils at a temperature of 100 degrees Celsius or less, or is intentionally dispersed into the environment, it must be considered to be a gas.

(c) If a control device is installed between the place of use and the point of release, multiply emissions from (b) by an adjustment factor. These are presented in Table 1.

Table 1—Adjustment to Emission Factors for Effluent Controls

Controls Types of radionuclides controlled Adjustment factor to emissions Comments and conditions HEPA filtersParticulates0.01Not applicable to gaseous radionuclides; periodic testing is prudent to ensure high removal efficiency. Fabric filterParticulates0.1Monitoring would be prudent to guard against tears in filter. Sintered metalParticulates1Insufficient data to make recommendation. Activated carbon filtersIodine gas0.1Efficiency is time dependent; monitoring is necessary to ensure effectiveness. Douglas bags: Held one week or longer for decayXenon0.5/wkBased on xenon half-life of 5.3 days; Douglas bags: Released within one weekXenon1Provides no reduction of exposure to general public. Venturi scrubbersParticulates
Gases
0.05
1
Although venturis may remove gases, variability in gaseous removal efficiency dictates adjustment factor for particulates only. Packed bed scrubbersGases0.1Not applicable to particulates. Electrostatic precipitatorsParticulates0.05Not applicable for gaseous radionuclides Xenon trapsXenon0.1Efficiency is time dependent; monitoring is necessary to ensure effectiveness. Fume hoodsAll1Provides no reduction to general public exposures. Vent stacksAll1Generally provides no reduction of exposure to general public.
References

(1) Environmental Protection Agency, “A Guide for Determining Compliance with the Clean Air Act Standards for Radionuclides Emissions from NRC-Licensed and Non-DOE Federal Facilities”, EPA 520/1-89-002, January 1989.

(2) Nuclear Regulatory Commission, “Methods for Estimating Radioactive and Toxic Airborne Source Terms for Uranium Milling Operations”, U.S. Nuclear Regulatory Commission Regulatory Guide 3.59, March 1987.

[54 FR 51711, Dec. 15, 1989]