- Table F-2 to Subpart F of Part 53—Particle Sizes and Wind Speeds for Full Wind Tunnel Test, Wind Tunnel Inlet Aspiration Test, and Static Chamber Test
Primary Partical Mean Size a (µm) | Full Wind Tunnel Test | Inlet Aspiration Test | Static Fractionator Test | Volatility Test | 2 km/hr | 24 km/hr | 2 km/hr | 24 km/hr | 1.5±0.25 | S | S | S | 2.0±0.25 | S | S | S | 2.2±0.25 | S | S | S | 2.5±0.25 | S | S | S | 2.8±0.25 | S | S | S | 3.0±0.25 | L | L | 3.5±0.25 | S | S | S | 4.0±0.5 | S | S | S | Polydisperse Glycerol Aerosol | L |
---|
a Aerodynamic diameter.
S = Solid particles.
L = Liquid particles.