View all text of Subpart R [§ 421.200 - § 421.207]

§ 421.206 - Pretreatment standards for new sources.

Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources. The mass of wastewater pollutants in secondary mercury process wastewater introduced into a POTW shall not exceed the following values:

(a) Spent battery electrolyte.

PSNS for the Secondary Mercury Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average mg/kg (pounds per million pounds) of mercury produced from batteries Lead0.0300.014 Mercury0.0160.006

(b) Acid wash and rinse water.

PSNS for the Secondary Mercury Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average mg/kg (pounds per million pounds) of mercury washed and rinsed Lead0.000560.00026 Mercury0.000300.00012

(c) Furnance wet air pollution control.

PSNS for the Secondary Mercury Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average mg/kg (pounds per million pounds of mercury processed through furnace Lead0.0000.000 Mercury0.0000.000