View all text of Subpart N [§ 421.140 - § 421.147]

§ 421.144 - Standards of performance for new sources.

Any new source subject to this subpart shall achieve the following new source performance standards:

(a) Sodium Antimonate Autoclave Wastewater.

NSPS for the Primary Antimony Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average mg/kg (pounds per million pounds) of antimony contained in sodium antimonate product Antimony30.15013.440 Arsenic21.7209.687 Mercury2.3440.937 Total suspended solids234.400187.500 pH( 1)( 1)

1 Within the range of 7.5 to 10.0 at all times.

(b) Fouled Anolyte.

NSPS for the Primary Antimony Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average mg/kg (pounds per million pounds) of antimony metal produced by electrowinning Antimony30.15013.440 Arsenic21.7209.687 Mercury2.3440.937 Total suspended solids234.400187.500 pH( 1)( 1)

1 Within the range of 7.5 to 10.0 at all times.

(c) Cathode Antimony Wash Water.

NSPS for the Primary Antimony Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average mg/kg (pounds per million pounds) of antimony metal produced by electrowinning Antimony60.31026.870 Arsenic43.43019.370 Mercury4.6871.875 Total suspended solids468.700375.000 pH( 1)( 1)

1 Within the range of 7.5 to 10.0 at all times.