- Table 6 to Subpart SSSSS of Part 63—Initial Compliance With Work Practice Standards
As stated in § 63.9806, you must show initial compliance with the work practice standards for affected sources according to the following table:
For each . . . | For the following standard . . . | You have demonstrated initial compliance if . . . | 1. Each affected source listed in Table 3 to this subpart | a. Each applicable work practice standard listed in Table 3 to this subpart | i. You have selected a method for performing each of the applicable work practice standards listed in Table 3 to this subpart; and | ii. You have included in your Initial Notification a description of the method selected for complying with each applicable work practice standard, as required by § 63.9(b); and | iii. You submit a signed statement with the Notification of Compliance Status that you have implemented the applicable work practice standard listed in Table 3 to this subpart; and | iv. You have described in your OM&M plan the method for complying with each applicable work practice standard specified in Table 3 to this subpart. | 2. Each basket or container that is used for holding fired refractory shapes in an existing shape preheater and autoclave during the pitch impregnation process | a. Control POM emissions from any affected shape preheater | i. You have implemented at least one of the work practice standards listed in item 1 of Table 3 to this subpart; and
ii. You have established a system for recording the date and cleaning method for each time you clean an affected basket or container. | 3. Each affected new or existing pitch working tank | Control POM emissions | You have captured and vented emissions from the affected pitch working tank to the device that is used to control emissions from an affected defumer or coking oven, or to a thermal or catalytic oxidizer that is comparable to the control device used on an affected defumer or coking oven. | 4. Each new or existing chromium refractory products kiln | Minimize fuel-based HAP emissions | You use natural gas, or equivalent, as the kiln fuel. | 5. Each existing clay refractory products kiln | Minimize fuel-based HAP emissions | You use natural gas, or equivalent, as the kiln fuel. | 6. Each new or existing curing oven, shape dryer, and kiln that is used to process refractory products that use organic HAP, on and after November 19, 2021 | Minimize fuel-based HAP emissions | You use natural gas, or equivalent, as the kiln fuel. |
---|