- Table 5 to Subpart HHHHHHH of Part 63—Operating Parameters, Operating Limits and Data Monitoring, Recording and Compliance Frequencies for Process Vents
For these control devices, you must monitor these operating parameters . . . | Establish the following operating limit during your initial performance
test . . . | Monitor, record, and demonstrate continuous compliance using these minimum
frequencies | Data measurement | Data recording | Data averaging period for compliance | Flow to/from the control device | N/A | Continuous | N/A | Date and time of flow start and stop. | Temperature (in fire box or downstream ductwork prior to heat exchange) | Minimum temperature | Continuous | Every 15 minutes | 3-hour block average. | Temperature differential across catalyst bed | Minimum temperature differential | Continuous | Every 15 minutes | 3-hour block average. | Inlet temperature to catalyst bed and catalyst condition | Minimum inlet temperature and catalyst condition as specified in 63.11940 (b)(3) | Continuous for temperature, annual for catalyst condition | Every 15 minutes for temperature, annual for catalyst condition | 3-hour block average for temperature, annual for catalyst condition. | Influent liquid flow | Minimum inlet liquid flow | Continuous | Every 15 minutes | 3-hour block average. | Influent liquid flow and gas stream flow | Minimum influent liquid flow to gas stream flow ratio | Continuous | Every 15 minutes | 3-hour block average. | Pressure drop | Minimum pressure drop | Continuous | Every 15 minutes | 3-hour block average. | Exhaust gas temperature | Maximum exhaust gas temperature | Continuous | Every 15 minutes | 3-hour block average. | Change in specific gravity of scrubber liquid | Minimum change in specific gravity | Continuous | Every 15 minutes | 3-hour block average. | pH of effluent liquid | Minimum pH | Continuous | Every 15 minutes | 3-hour block average. | Causticity of effluent liquid | Minimum causticity | Continuous | Every 15 minutes | 3-hour block average. | Conductivity of effluent liquid | Minimum conductivity | Continuous | Every 15 minutes | 3-hour block average. | Regeneration stream flow. | Minimum total flow per regeneration cycle | Continuous | N/A | Total flow for each regeneration cycle. | Adsorber bed temperature. | Maximum temperature | Continuously after regeneration and within 15 minutes of completing any temperature regulation | Every 15 minutes after regeneration and within 15 minutes of completing any temperature regulation | 3-hour block average. | Adsorber bed temperature. | Minimum temperature | Continuously during regeneration except during any temperature regulating portion of the regeneration cycle | N/A | Average of regeneration cycle. | Vacuum and duratio of regeneration | Minimum vacuum and period of time for regeneration | Continuous | N/A | Average vacuum and duration of regeneration. | Regeneration frequency | Minimum regeneration frequency and duration | Continuous | N/A | Date and time of regeneration start and stop. | Adsorber operation valve sequencing and cycle time | Correct valve sequencing and minimum cycle time | Daily | Daily | N/A. | Average adsorber bed life. | N/A | Daily until breakthrough for 3 adsorber bed change-outs | N/A | N/A. | Outlet VOC concentration of the first adsorber bed in series | Limits in Table 1 or 2 of this subpart | Daily, except monthly (if more than 2 months bed life remaining) or weekly (if more than 2 weeks bed life remaining) | N/A | Daily, weekly, or monthly. | Temperature | Maximum outlet temperature | Continuous | Every 15 minutes | 3-hour block average. |
---|