- Table 1 to Subpart KKKKK of Part 63—Emission Limits

Table 1 to Subpart KKKKK of Part 63—Emission Limits

As stated in § 63.8555, you must meet each emission limit in the following table that applies to you:

For each . . . You must meet the following emission limits . . . 1. Collection of all tunnel or roller kilns at facilityHF and HCl emissions must not exceed 62 kilograms per hour (kg/hr) (140 pounds per hour (lb/hr)) HCl equivalent, under the health-based standard, as determined using Equations 4 and 5 of this subpart. 2. Existing floor tile roller kilna. PM emissions must not exceed 0.063 kilogram per megagram (kg/Mg) (0.13 pound per ton (lb/ton)) of fired product. b. Hg emissions must not exceed 6.3 E-05 kg/Mg (1.3 E-04 lb/ton) of fired product. c. Dioxin/furan emissions must not exceed 2.8 nanograms per kilogram (ng/kg) of fired product. 3. Existing wall tile roller kilna. PM emissions must not exceed 0.19 kg/Mg (0.37 lb/ton) of fired product. b. Hg emissions must not exceed 1.1 E-04 kg/Mg (2.1 E-04 lb/ton) of fired product. c. Dioxin/furan emissions must not exceed 0.22 ng/kg of fired product. 4. Existing first-fire sanitaryware tunnel kilna. PM emissions must not exceed 0.17 kg/Mg (0.34 lb/ton) of greenware fired. b. Hg emissions must not exceed 1.3 E-04 kg/Mg (2.6 E-04 lb/ton) of greenware fired. c. Dioxin/furan emissions must not exceed 3.3 ng/kg of greenware fired. 5. Existing tile glaze line with glaze sprayinga. PM emissions must not exceed 0.93 kg/Mg (1.9 lb/ton) of first-fire glaze sprayed (dry weight basis). b. Hg emissions must not exceed 8.0 E-05 kg/Mg (1.6 E-04 lb/ton) of first-fire glaze sprayed (dry weight basis). 6. Existing sanitaryware manual glaze applicationPM emissions must not exceed 18 kg/Mg (35 lb/ton) of first-fire glaze sprayed (dry weight basis). 7. Existing sanitaryware spray machine glaze applicationPM emissions must not exceed 6.2 kg/Mg (13 lb/ton) of first-fire glaze sprayed (dry weight basis). 8. Existing sanitaryware robot glaze applicationPM emissions must not exceed 4.5 kg/Mg (8.9 lb/ton) of first-fire glaze sprayed (dry weight basis). 9. Existing floor tile spray dryerDioxin/furan emissions must not exceed 19 ng/kg of throughput processed. 10. Existing wall tile spray dryerDioxin/furan emissions must not exceed 0.058 ng/kg of throughput processed. 11. Existing floor tile press dryerDioxin/furan emissions must not exceed 0.024 ng/kg of throughput processed. 12. New or reconstructed floor tile roller kilna. PM emissions must not exceed 0.019 kg/Mg (0.037 lb/ton) of fired product. b. Hg emissions must not exceed 2.0 E-05 kg/Mg (3.9 E-05 lb/ton) of fired product. c. Dioxin/furan emissions must not exceed 1.3 ng/kg of fired product. 13. New or reconstructed wall tile roller kilna. PM emissions must not exceed 0.19 kg/Mg (0.37 lb/ton) of fired product. b. Hg emissions must not exceed 1.1 E-04 kg/Mg (2.1 E-04 lb/ton) of fired product. c. Dioxin/furan emissions must not exceed 0.22 ng/kg of fired product. 14. New or reconstructed first-fire sanitaryware tunnel kilna. PM emissions must not exceed 0.048 kg/Mg (0.095 lb/ton) of greenware fired. b. Hg emissions must not exceed 6.1 E-05 kg/Mg (1.3 E-04 lb/ton) of greenware fired. c. Dioxin/furan emissions must not exceed 0.99 ng/kg of greenware fired. 15. New or reconstructed tile glaze line with glaze sprayinga. PM emissions must not exceed 0.31 kg/Mg (0.61 lb/ton) of first-fire glaze sprayed (dry weight basis). b. Hg emissions must not exceed 8.0 E-05 kg/Mg (1.6 E-04 lb/ton) of first-fire glaze sprayed (dry weight basis). 16. New or reconstructed sanitaryware manual glaze applicationPM emissions must not exceed 2.0 kg/Mg (3.9 lb/ton) of first-fire glaze sprayed (dry weight basis). 17. New or reconstructed sanitaryware spray machine glaze applicationPM emissions must not exceed 1.6 kg/Mg (3.2 lb/ton) of first-fire glaze sprayed (dry weight basis). 18. New or reconstructed sanitaryware robot glaze applicationPM emissions must not exceed 1.2 kg/Mg (2.3 lb/ton) of first-fire glaze sprayed (dry weight basis). 19. New or reconstructed floor tile spray dryerDioxin/furan emissions must not exceed 0.071 ng/kg of throughput processed. 20. New or reconstructed wall tile spray dryerDioxin/furan emissions must not exceed 0.058 ng/kg of throughput processed. 21. New or reconstructed floor tile press dryerDioxin/furan emissions must not exceed 0.024 ng/kg of throughput processed. 22. Collection of emissions averaging sourcesPM emissions must not exceed the applicable emission limit, under the emissions averaging option, as determined using Equations 9 through 11 of this subpart. 23. Collection of emissions averaging sourcesHg emissions must not exceed the applicable emission limit, under the emissions averaging option, as determined using Equations 9 through 11 of this subpart.
[84 FR 58609, Nov. 1, 2019]