- Table 10 to Subpart DDDDD of Part 63—Applicability of General Provisions to Subpart DDDDD
As stated in § 63.7565, you must comply with the applicable General Provisions according to the following:
Citation | Subject | Applies to subpart DDDDD | § 63.1 | Applicability | Yes. | § 63.2 | Definitions | Yes. Additional terms defined in § 63.7575 | § 63.3 | Units and Abbreviations | Yes. | § 63.4 | Prohibited Activities and Circumvention | Yes. | § 63.5 | Preconstruction Review and Notification Requirements | Yes. | § 63.6(a), (b)(1)-(b)(5), (b)(7), (c) | Compliance with Standards and Maintenance Requirements | Yes. | § 63.6(e)(1)(i) | General duty to minimize emissions. | No. See § 63.7500(a)(3) for the general duty requirement. | § 63.6(e)(1)(ii) | Requirement to correct malfunctions as soon as practicable. | No. | § 63.6(e)(3) | Startup, shutdown, and malfunction plan requirements. | No. | § 63.6(f)(1) | Startup, shutdown, and malfunction exemptions for compliance with non-opacity emission standards. | No. | § 63.6(f)(2) and (3) | Compliance with non-opacity emission standards. | Yes. | § 63.6(g) | Use of alternative standards | Yes, except § 63.7555(d)(13) specifies the procedure for application and approval of an alternative timeframe with the PM controls requirement in the startup work practice (2). | § 63.6(h)(1) | Startup, shutdown, and malfunction exemptions to opacity standards. | No. See § 63.7500(a). | § 63.6(h)(2) to (h)(9) | Determining compliance with opacity emission standards | No. Subpart DDDDD specifies opacity as an operating limit not an emission standard. | § 63.6(i) | Extension of compliance | Yes. Note: Facilities may also request extensions of compliance for the installation of combined heat and power, waste heat recovery, or gas pipeline or fuel feeding infrastructure as a means of complying with this subpart. | § 63.6(j) | Presidential exemption. | Yes. | § 63.7(a), (b), (c), and (d) | Performance Testing Requirements | Yes. | § 63.7(e)(1) | Conditions for conducting performance tests | No. Subpart DDDDD specifies conditions for conducting performance tests at § 63.7520(a) to (c). | § 63.7(e)(2)-(e)(9), (f), (g), and (h) | Performance Testing Requirements | Yes. | § 63.8(a) and (b) | Applicability and Conduct of Monitoring | Yes. | § 63.8(c)(1) | Operation and maintenance of CMS | Yes. | § 63.8(c)(1)(i) | General duty to minimize emissions and CMS operation | No. See § 63.7500(a)(3). | § 63.8(c)(1)(ii) | Operation and maintenance of CMS | Yes. | § 63.8(c)(1)(iii) | Startup, shutdown, and malfunction plans for CMS | No. | § 63.8(c)(2) to (c)(9) | Operation and maintenance of CMS | Yes. | § 63.8(d)(1) and (2) | Monitoring Requirements, Quality Control Program | Yes. | § 63.8(d)(3) | Written procedures for CMS | Yes, except for the last sentence, which refers to a startup, shutdown, and malfunction plan. Startup, shutdown, and malfunction plans are not required. | § 63.8(e) | Performance evaluation of a CMS | Yes. | § 63.8(f) | Use of an alternative monitoring method. | Yes. | § 63.8(g) | Reduction of monitoring data | Yes. | § 63.9 | Notification Requirements | Yes. | § 63.10(a), (b)(1) | Recordkeeping and Reporting Requirements | Yes. | § 63.10(b)(2)(i) | Recordkeeping of occurrence and duration of startups or shutdowns | Yes. | § 63.10(b)(2)(ii) | Recordkeeping of malfunctions | No. See § 63.7555(d)(7) for recordkeeping of occurrence and duration and § 63.7555(d)(8) for actions taken during malfunctions. | § 63.10(b)(2)(iii) | Maintenance records | Yes. | § 63.10(b)(2)(iv) and (v) | Actions taken to minimize emissions during startup, shutdown, or malfunction | No. | § 63.10(b)(2)(vi) | Recordkeeping for CMS malfunctions | Yes. | § 63.10(b)(2)(vii) to (xiv) | Other CMS requirements | Yes. | § 63.10(b)(3) | Recordkeeping requirements for applicability determinations | No. | § 63.10(c)(1) to (9) | Recordkeeping for sources with CMS | Yes. | § 63.10(c)(10) and (11) | Recording nature and cause of malfunctions, and corrective actions | No. See § 63.7555(d)(7) for recordkeeping of occurrence and duration and § 63.7555(d)(8) for actions taken during malfunctions. | § 63.10(c)(12) and (13) | Recordkeeping for sources with CMS | Yes. | § 63.10(c)(15) | Use of startup, shutdown, and malfunction plan | No. | § 63.10(d)(1) and (2) | General reporting requirements | Yes. | § 63.10(d)(3) | Reporting opacity or visible emission observation results | No. | § 63.10(d)(4) | Progress reports under an extension of compliance | Yes. | § 63.10(d)(5) | Startup, shutdown, and malfunction reports | No. See § 63.7550(c)(11) for malfunction reporting requirements. | § 63.10(e) | Additional reporting requirements for sources with CMS | Yes. | § 63.10(f) | Waiver of recordkeeping or reporting requirements | Yes. | § 63.11 | Control Device Requirements | No. | § 63.12 | State Authority and Delegation | Yes. | § 63.13-63.16 | Addresses, Incorporation by Reference, Availability of Information, Performance Track Provisions | Yes. | § 63.1(a)(5),(a)(7)-(a)(9), (b)(2), (c)(3)-(4), (d), 63.6(b)(6), (c)(3), (c)(4), (d), (e)(2), (e)(3)(ii), (h)(3), (h)(5)(iv), 63.8(a)(3), 63.9(b)(3), (h)(4), 63.10(c)(2)-(4), (c)(9). | Reserved | No. |
---|