- Table 31 to Subpart UUU of Part 63—Continuous Monitoring Systems for HAP Emissions From Sulfur Recovery Units
As stated in § 63.1568(b)(1), you shall meet each requirement in the following table that applies to you.
For . . . | For this limit . . . | You shall install and operate this continuous monitoring system . . . | 1. Subject to NSPS. Each new or existing Claus sulfur recovery unit part of a sulfur recovery plant with design capacity greater than 20 LTD and subject to the NSPS for sulfur oxides in 40 CFR 60.104(a)(2) or 60.102a(f)(1). | a. 250 ppmv (dry basis) of SO | Continuous emission monitoring system to measure and record the hourly average concentration of SO | b. 300 ppmv of reduced sulfur compounds calculated as ppmv SO | Continuous emission monitoring system to measure and record the hourly average concentration of reduced sulfur and oxygen (O | c. If you use Equation 1 of 40 CFR 60.102a(f)(1)(i) to set your emission limit | i. Complete either item 1.a or item 1.b; and
ii. Either a continuous emission monitoring system to measure and record the O | 2. Option 1: Elect NSPS. Each new or existing sulfur recovery unit (Claus or other type, regardless of size) not subject to the NSPS for sulfur oxides in 40 CFR 60.104(a)(2) or 60.102a(f)(1). | a. 250 ppmv (dry basis) of SO | Continuous emission monitoring system to measure and record the hourly average concentration of SO | b. 300 ppmv of reduced sulfur compounds calculated as ppmv SO | Continuous emission monitoring system to measure and record the hourly average concentration of reduced sulfur and O | c. If you use Equation 1 of 40 CFR 60.102a(f)(1)(i) to set your emission limit | i. Complete either item 2.a or item 2.b; and
ii. Either a continuous emission monitoring system to measure and record the O | 3. Option 2: TRS limit. Each new or existing sulfur recovery unit (Claus or other type, regardless of size) not subject to the NSPS for sulfur oxides in 40 CFR 60.104(a)(2) or 60.102a(f)(1). | a. 300 ppmv of total reduced sulfur (TRS) compounds, expressed as an equivalent SO | i. Continuous emission monitoring system to measure and record the hourly average concentration of TRS for each exhaust stack; this monitor must include an oxygen monitor for correcting the data for excess oxygen; or | ii. Continuous parameter monitoring systems to measure and record the combustion zone temperature of each thermal incinerator and the oxygen content (percent, dry basis) in the vent stream of the incinerator. | 4. Startup or shutdown option 1: electing to comply with § 63.1568(a)(4)(ii). Each new or existing sulfur recovery unit (Claus or other type, regardless of size) during periods of startup or shutdown. | Any | On and after January 30, 2019, monitoring systems as specified in §§ 63.670 and 63.671. Prior to January 30, 2019, either continuous parameter monitoring systems following the requirements in § 63.11 (to detect the presence of a flame; to measure and record the net heating value of the gas being combusted; and to measure and record the volumetric flow of the gas being combusted) or monitoring systems as specified in §§ 63.670 and 63.671. | 5. Startup or shutdown option 2: electing to comply with § 63.1568(a)(4)(iii). Each new or existing sulfur recovery unit (Claus or other type, regardless of size) during periods of startup or shutdown. | Any | Continuous parameter monitoring systems to measure and record the firebox temperature of each thermal incinerator or oxidizer and the oxygen content (percent, dry basis) in the exhaust vent from the incinerator or oxidizer. |
---|