- Table 4 to Subpart OOO of Part 63—Operating Parameter Levels

Device Parameters to be monitored Established operating
parameter(s)
ScrubberpH of scrubber effluent; and scrubber liquid and gas flow ratesMinimum pH; and minimum liquid/gas ratio AbsorberExit temperature of the absorbing liquid; and exit specific gravity of the absorbing liquidMaximum temperature; and maximum specific gravity CondenserExit temperatureMaximum temperature Carbon absorberTotal regeneration steam or nitrogen flow, or pressure (gauge or absolute) a during carbon bed regeneration cycle; and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s))Maximum flow or pressure; and maximum temperature Thermal incineratorFirebox temperatureMinimum temperature Catalytic incineratorTemperature upstream and downstream of the catalyst bedMinimum upstream temperature; and minimum temperature difference across the catalyst bed Boiler or process heaterFirebox temperatureMinimum temperature Other devices (or as an alternate to the requirements previously presented in this table) bOrganic HAP concentration level or reading at outlet of deviceMaximum organic HAP concentration or reading

a 25 to 50 mm (absolute) is a common pressure level obtained by pressure swing absorbers.

b Concentration is measured instead of an operating parameter.