- Table 4 to Subpart BB of Part 63—Operating Parameters, Operating Limits and Data Monitoring, Recordkeeping and Compliance Frequencies

For the operating parameter applicable to you, as specified in Table 3 . . . You must establish the following operating limit during your performance test . . . And you must monitor, record, and demonstrate continuous compliance using these minimum frequencies . . . Data measurement Data recording Data averaging
period for
compliance
Absorbers (Wet Scrubbers)Influent liquid flowMinimum inlet liquid flowContinuousEvery 15 minutesDaily. Influent liquid flow rate and gas stream flow rateMinimum influent liquid-to-gas ratio aContinuousEvery 15 minutesDaily. For the operating parameter applicable to you, as specified in Table 3You must establish the following operating limitAnd you must monitor, record, and demonstrate continuous compliance using these minimum frequencies . . . Data measurementData recordingData averaging
period for
compliance.
Pressure dropPressure drop rangeContinuousEvery 15 minutesDaily. Sorbent InjectionSorbent injection rateMinimum injection rateContinuousEvery 15 minutesDaily. Sorbent injection carrier gas flow rateMinimum carrier gas flow rateContinuousEvery 15 minutesDaily. Fabric FiltersAlarm timeMaximum alarm time is not established on a site-specific basis but is specified in § 63.605(f)(9)ContinuousEach date and time of alarm start and stopMaximum alarm time specified in § 63.605(f)(9). Wet Electrostatic PrecipitatorSecondary voltageSecondary voltage rangeContinuousEvery 15 minutesDaily.
[82 FR 45201, Sept. 28, 2017]