- Table 27 to Subpart G of Part 63—Summary of Internal Floating Deck Fitting Loss Factors (KF) and Typical Number of Fittings (NF)

Deck fitting type Deck fitting loss factor (KF) aTypical number of fittings (NF) Access hatch1. Bolted cover, gasketed1.6 Unbolted cover, gasketed11 Unbolted cover, ungasketedb 25 Automatic gauge float well1. Bolted cover, gasketed5.1 Unbolted cover, gasketed15 Unbolted cover, ungasketedb 28 Column well(see Table 24). Builtup column-sliding cover, gasketed33 Builtup column-sliding cover, ungasketedb 47
10
Pipe column-flexible fabric sleeve seal19 Pipe column-sliding cover, gasketed32 Pipe column-sliding cover, ungasketed Ladder well1. Sliding cover, gasketed56 Sliding cover, ungasketedb 76 Roof leg or hanger well(5 + D/10 + D 2/600) c. Adjustableb 7.9 Fixed0 Sample pipe or well1. Slotted pipe-sliding cover, gasketed44 Slotted pipe-sliding cover, ungasketed57 Sample well-slit fabric seal, 10 percent open areab 12 Stub drain, 1-in diameter d1.2(D 2/125) c. Vacuum breaker1. Weighted mechanical actuation, gasketedb 0.7 Weighted mechanical actuation, ungasketed0.9

a Units for KF are pound-moles per year.

b If no specific information is available, this value can be assumed to represent the most common/typical deck fittings currently used.

c D = Tank diameter (feet).

d Not used on welded contact internal floating decks.