View all text of Subjgrp 174 [§ 27.601 - § 27.629]
§ 27.619 - Special factors.
(a) The special factors prescribed in §§ 27.621 through 27.625 apply to each part of the structure whose strength is—
(1) Uncertain;
(2) Likely to deteriorate in service before normal replacement; or
(3) Subject to appreciable variability due to—
(i) Uncertainties in manufacturing processes; or
(ii) Uncertainties in inspection methods.
(b) For each part to which §§ 27.621 through 27.625 apply, the factor of safety prescribed in § 27.303 must be multiplied by a special factor equal to—
(1) The applicable special factors prescribed in §§ 27.621 through 27.625; or
(2) Any other factor great enough to ensure that the probability of the part being understrength because of the uncertainties specified in paragraph (a) of this section is extremely remote.