Collapse to view only § 56.35-10 - Nonmetallic expansion joints (replaces 119.5.1).

§ 56.35-1 - Pipe stress calculations (replaces 119.7).

(a) A summary of the results of pipe stress calculations for the main and auxiliary steam piping where the design temperatures exceed 800 °F must be submitted for approval. Calculations must be made in accordance with a method of stress analysis acceptable to the Marine Safety Center to determine the forces at all terminal connections, anchor, and junction points, as well as the resultant bending stress, longitudinal pressure stress, torsional stress, and combined expansion stress at all such points. The location of the maximum combined stress must be indicated in each run of pipe between anchor points.

(b) The Marine Safety Center (MSC) will give special consideration to the use of the full tabulated value of “S” in computing Sh and Sc where all material used in the system is subjected to further nondestructive testing specified by the MSC, and where the calculations prescribed in 119.6.4 and 102.3.2 of ASME B31.1 (incorporated by reference; see § 56.01-2) and § 56.07-10 are performed. The procedures for nondestructive testing and the method of stress analysis must be approved by the MSC before the submission of computations and drawings for approval.

[CGD 77-140, 54 FR 40607, Oct. 2, 1989, as amended by USCG-2003-16630, 73 FR 65178, Oct. 31, 2008]

§ 56.35-10 - Nonmetallic expansion joints (replaces 119.5.1).

(a) Nonmetallic expansion joints must conform to the standards listed in table 2 to § 56.60-1. Nonmetallic expansion joints may be used within their specified pressure and temperature rating in vital and nonvital machinery sea connections inboard of the skin valve. These joints must not be used to correct for improper workmanship or misalignment. Joint movements must not exceed the limits set by the joint manufacturer.

(b) [Reserved]

[CGD 77-140, 54 FR 40607, Oct. 2, 1989]

§ 56.35-15 - Metallic expansion joints (replaces 119.5.1).

Metallic expansion joints must conform to the standards listed in table 2 to § 56.60-1 and may be used within their specified pressure and temperature rating.

[CGD 77-140, 54 FR 40607, Oct. 2, 1989]