View all text of Subjgrp 276 [§ 29.1351 - § 29.1363]

§ 29.1353 - Energy storage systems.

Energy storage systems must be designed and installed as follows:

(a) Energy storage systems must provide automatic protective features for any conditions that could prevent continued safe flight and landing.

(b) Energy storage systems must not emit any flammable, explosive, or toxic gases, smoke, or fluids that could accumulate in hazardous quantities within the rotorcraft.

(c) Corrosive fluids or gases that escape from the system must not damage surrounding structures, adjacent equipment, or systems necessary for continued safe flight and landing.

(d) The maximum amount of heat and pressure that can be generated during any operation or under any failure condition of the energy storage system or its individual components must not result in any hazardous effect on rotorcraft structure, equipment, or systems necessary for continued safe flight and landing.

(e) Energy storage system installations required for continued safe flight and landing of the rotorcraft must have monitoring features and a means to indicate to the pilot the status of all critical system parameters.

[Amdt. 29-59, 88 FR 8740, Feb. 10, 2023]