Each electric power operated lifeboat winch must meet § 111.95 in subchapter J and § 160.015 in subchapter Q of this chapter, or other standard specified by the Commandant.
§ 120.530 - Hazardous areas.
(a) Electrical equipment in lockers used to store paint, oil, turpentine, or other flammable liquids must be explosion-proof or be part of an intrinsically safe system.
(b) Explosion-proof equipment and intrinsically safe systems must meet the requirements of § 111.105 in subchapter J of this chapter.
§ 120.540 - Elevators.
Each elevator on a vessel must meet the requirements of American National Standards Institute (ANSI) A17.1. “Safety Code for Elevators, and Escalators,” or other standard specified by the Commandant.
§ 120.550 - General alarm systems.
(a) All vessels with overnight accommodations must be equipped with a general alarm system.
(b) A vessel of more than 19.8 meters (65 feet) in length with overnight accommodations for more than 49 passengers must have a general alarm that meets the requirements of § 113.25 in subchapter J of this chapter.
(c) The public address system required by § 121.610 of this chapter may be used to sound the general alarm signal.