Collapse to view only § 116.1160 - Watertight integrity.
- § 116.1110 - Drainage of flush deck vessels.
- § 116.1120 - Drainage of cockpit vessels, well deck vessels, and open boats.
- § 116.1160 - Watertight integrity.
§ 116.1110 - Drainage of flush deck vessels.
(a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must be watertight and have no obstruction to overboard drainage.
(b) Each flush deck vessel may have solid bulwarks in the forward one-third length of the vessel if:
(1) The bulwarks do not form a well enclosed on all sides; and
(2) The foredeck of the vessel has sufficient sheer to ensure drainage aft.
§ 116.1120 - Drainage of cockpit vessels, well deck vessels, and open boats.
Drainage of cockpit vessels, well deck vessels, and open boats must meet the applicable requirements of §§ 178.420, 178.430, 178.440, 178.450 in subchapter T of this chapter.
§ 116.1160 - Watertight integrity.
(a) A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight:
(1) A hatch on a watertight trunk that extends at least 305 millimeters (12 inches) above the weather deck;
(2) A hatch in a cabin top; and
(3) A hatch on a vessel that operates only on protected waters.
(b) A hatch cover must:
(1) Have securing devices; and
(2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
(c) A hatch cover that provides access to accommodation spaces must be operable from either side.
(d) A weathertight door must be provided for each opening located in a deck house or companionway. Permanent watertight coamings must be provided as follows:
(1) On a vessel on an exposed or partially protected route, a watertight coaming with a height of at least 150 millimeters (6 inches) must be provided under each weathertight door in a cockpit or a well, or on the main deck of a flush deck vessel.
(2) On a vessel on a protected route, a watertight coaming with a height of at least 75 millimeters (3 inches) must be provided under each weathertight door in a cockpit or a well.
(3) The height of the watertight coaming for a hinged watertight door, need only be sufficient to accommodate the door.