§ 116.400 - Application.
(a) This subpart applies to:
(1) Vessels carrying more than 150 passengers; or
(2) Vessels with overnight accommodations for more than 49 passengers but not more than 150 passengers.
(b) A vessel with overnight accommodations for more than 150 passengers must comply with § 72.05 in subchapter H of this chapter.
(c) Vessels meeting the structural fire protection requirements of SOLAS, Chapter II-2, Regulations 5, 6, 8, 9, and 11 (incorporated by reference, see § 114.600 of this chapter), when combined with the requirements in § 116.438, may be considered equivalent to the provisions of this subpart.
§ 116.405 - General arrangement and outfitting.
(a) Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable.
(b) Combustible materials to be limited. Limited amounts of combustible materials such as wiring insulation, pipe hanger linings, nonmetallic (plastic) pipe, and cable ties are permitted in concealed spaces except as otherwise prohibited by this subpart.
(c) Combustibles insulated from heated surfaces. Internal combustion engine exhausts, boiler and galley uptakes, and similar sources of ignition must be kept clear of and suitably insulated from combustible material.
(d) Separation of machinery and fuel tank spaces from accommodation spaces. Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors.
(e) Paint and flammable liquid lockers. Paint and flammable liquid lockers must be constructed of steel or equivalent material, or wholly lined with steel or equivalent material.
(f) Nonmetallic piping in concealed spaces. The use of nonmetallic (plastic) pipe within a concealed space in a control space, accommodation space, or service space is permitted in nonvital service only if the piping material has been approved under § 164.141 of this chapter and meets both low flame spread rating and toxicity requirements.
(g) Vapor barriers. Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers.
(h) Interior finishes. Combustible interior finishes allowed by § 116.422(d) of this part must not extend into hidden spaces, such as behind linings, above ceilings, or between bulkheads.
(i) Waste Receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom.
(j) Mattresses. All mattresses must comply with either:
(1) The U.S. Department of Commerce Standard for Mattress Flammability (FF 4-72.16), 16 CFR Part 1632, Subpart A and not contain polyurethane foam; or,
(2) International Maritime Organization Resolution A.688(17) “Fire Test Procedures For Ignitability of Bedding Components.” Mattresses that are tested to this standard may contain polyurethane foam.
§ 116.415 - Fire control boundaries.
(a) Type and construction of fire control bulkheads and decks—(1) Major hull structure. The hull, structural bulkheads, columns and stanchions, superstructures, and deckhouses must be composed of steel or equivalent material.
(2) Bulkheads and decks—Bulkheads and decks must be classed as A-60, A-30, A-15, A-0, B-15, B-0, C, or C' based on the following:
(i) A-Class bulkheads or decks must be composed of steel or equivalent material, suitably stiffened and made intact with the main structure of the vessel, such as the shell, structural bulkheads, and decks. They must be so constructed that, if subjected to the standard fire test, they are capable of preventing the passage of smoke and flame for 1 hour. In addition, they must be so insulated with approved structural insulation, bulkhead panels, or deck covering so that, if subjected to the standard fire test for the applicable time period listed below, the average temperature on the unexposed side does not rise more than 139 °C (250 °F) above the original temperature, nor does the temperature at any one point, including any joint, rise more than 181 °C (325 °F) above the original temperature:
A-60 Class | 60 minutes | A-30 Class | 30 minutes | A-15 Class | 15 minutes | A-0 Class | 0 minutes |
(ii) Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated.
(iii) B-Class bulkheads and decks must be constructed of noncombustible materials and made intact with the main structure of the vessel, such as shell, structural bulkheads, and decks, except that a B-Class bulkhead need not extend above an approved continuous B-Class ceiling. They must be so constructed that, if subjected to the standard fire test, they are capable of preventing the passage of flame for 30 minutes. In addition, their insulation value must be such that, if subjected to the standard fire test for the applicable time period listed below, the average temperature of the unexposed side does not rise more than 139 °C (250 °F) above the original temperature, nor does the temperature at any one point, including any joint, rise more than 225 °C (405 °F) above the original temperature:
B-15 Class | 15 minutes | B-0 Class | 0 minutes |
(iv) Penetrations in B-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame for 30 minutes. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated.
(v) C-Class bulkheads and decks must be composed of noncombustible materials.
(vi) C′-Class bulkheads and decks must be constructed of noncombustible materials and made intact with the main structure of the vessel, such as shell, structural bulkheads, and decks, except that a C′-Class bulkhead need not extend above a continuous B-Class or C′-Class ceiling. C′-Class bulkheads must be constructed to prevent the passage of smoke between adjacent areas. Penetrations in C′-Class boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed so as to preserve the smoke-tight integrity of the boundary.
(vii) Any sheathing, furring, or holding pieces incidental to the securing of structural insulation must be approved noncombustible material.
(b) Bulkhead requirements. Bulkheads between various spaces must meet the requirements of Table 116.415(b).
Table 116.415 (
Spaces | (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | (11) | (12) | (13) | Control Space (1) | B-0 | A-0 | A-0 | A-0 | A-15 | A-60 | A-60 | A-0 | A-60 | A-60 | A-60 | A-0 | A-0 | Stairway (2) | A-0 4 | A-0 | A-0 | A-0 | A-60 | A-60 | A-0 | A-15 | A-15 | A-15 | A-0 | A-0 | Corridor (3) | C | A-0 | B-0 | B-0 | A-0 | B-0 | A-0 | A-0 | A-0 | A-0 | A-0 | Embarkation Station (4) | C | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | C' 1 | C | Low Risk Accommodation (5) | B-0 | B-15 | B-15 | B-0 2 | A-15 | A-15 | A-15 | A-0 | A-0 | High Risk Accommodation (6) (≤50 sq. m.) | B-15 | A-30 | B-0 2 | A-60 | A-60 | A-60 | A-0 | A-0 | High Risk Accommodation (7) (>50 sq. m.) | A-60 | B-0 2 | A-60 | A-60 | A-60 | A-0 | A-0 | Low Risk Service Spaces (8) | C | A-0 | A-0 | A-0 | A-0 | A-0 | High Risk Service Spaces (9) | C 3 | A-0 | A-0 | A-0 | A-0 | Machinery Spaces (10) | C | A-0 | A-0 | A-0 | Cargo Spaces (11) | A-0 | A-0 | A-0 | Auxiliary Machinery spaces, voids, fuel and water tanks (12) | C' 1 | C' 1 | Open decks (not safety areas) (13) | C |
---|
1 Boundaries of fuel tanks, auxiliary machinery spaces, and voids that contain a fire load in excess of 2.5kg/m 2 (0.5 pounds per square foot) must be minimum A-0 Class construction.
2 Toilet space boundaries may be reduced to C′-Class.
3 C-Class bulkheads may be used between two similar spaces, such as between two storerooms; however, an A-0 Class bulkhead shall be used between two dissimilar spaces, such as a storeroom and a workshop.
4 Separation is not required within a single stairtower. A-0 construction is required between two distinct stairtowers.
(c) Deck requirements. Decks between various spaces must meet the requirements of Table 116.415(c), except that where linings or bulkhead panels are framed away from the shell or structural bulkheads, the deck within the void space so formed need only meet A-0 Class requirements.
Table 116.415(
Space Above | (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | (11) | (12) | (13) | Space Below: | Control Space (1) | A-0 | A-0 | A-15 | A-0 | A-0 | A-15 | A-30 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | Stairway (2) | A-0 | C | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | Corridor (3) | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-15 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | Embarkation Station (4) | A-0 | A-0 | A-0 | C | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | C' 1 | C | Low Risk Accommodation (5) | A-15 | A-15 | A-0 | A-0 | A-0 | A-0 | A-15 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | High Risk Accommodation(6) (≤50 sq. m.) | A-60 | A-60 | A-30 | A-15 | A-0 | A-30 | A-60 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | High Risk Accommodation (7) (>50 sq. m.) | A-60 | A-60 | A-60 | A-30 | A-15 | A-60 | A-60 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | Low Risk Service Spaces (8) | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | High Risk Service Spaces (9) | A-60 | A-30 | A-30 | A-30 | A-15 | A-60 | A-60 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | Machinery Spaces (10) | A-60 | A-60 | A-60 | A-30 | A-15 | A-60 | A-60 | A-0 | A-0 | C | A-0 | A-0 | A-0 | Cargo Spaces (11) | A-60 | A-30 | A-30 | A-30 | A-15 | A-60 | A-60 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | Auxiliary Machinery Spaces, voids, fuel and water tanks (12) | A-0 | A-0 | A-0 | C' 1 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | C' 1 | A-0 1 | Open decks (not safety areas) (13) | A-0 | A-0 | A-0 | C | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 1 | C |
---|
1 Boundaries of fuel tanks, auxiliary machinery spaces, and voids that contain a fire load in excess of 2.5 kg/m 2 (0.5 pounds per square foot) must be minimum A-0 Class construction.
(d) Main vertical zones. (1) The hull, superstructure, and deck houses of a vessel, except for a vehicle space on a vehicle ferry, must be subdivided by bulkheads into main vertical zones which:
(i) Are generally not more than 40 meters (131 feet) in mean length on any one deck;
(ii) Must be constructed to:
(A) The greater of A-30 Class or the requirements of paragraph (b) of this section, or;
(B) Minimum A-0 Class where there is a Type 8, 12 or 13 space on either side of the division; and
(iii) May have small horizontal steps, if the steps:
(A) Do not exceed 20% of the mean length of the main vertical zone or 8 meters (26 feet), whichever is smaller; and
(B) Must be constructed to A-60 Class, or minimum A-0 Class where there is a Type 8, 12 or 13 space on either side of the division.
(iv) May be extended to a maximum mean length of 44 meters (144 feet) on each deck by the Commanding Officer, Marine Safety Center provided the maximum distance between the furthermost points of the bulkheads bounding the main vertical zone also does not exceed 44 meters (144 feet).
(2) Vehicle decks on a vehicle ferry must be subdivided. Where main vertical zones are impractical due to the vehicle carrying configuration, main horizontal zones may be provided. The decks bounding such a zone must be of at least A-30 construction or meet the requirements of paragraph (c) of this section, whichever is greater.
(e) Draft stops. In concealed spaces above ceilings and between linings and the shell of a vessel, draft stops must be fitted not more than 13.7 meters (45 feet) apart in the horizontal direction and at each deck level in the vertical direction unless otherwise permitted in paragraph (f). Draft stops must be of at least B-Class construction and be fitted in a vertical position.
(f) On vessels with no overnight passenger accommodations, draft stops are not required above/around large public spaces provided all of the following conditions are met:
(1) The space in question is surrounded by A-Class divisions or extends to the outer shell of the vessel.
(2) The space in question is open and unobstructed such that a fire in any part of the space will quickly be discovered.
(3) The area above the ceiling is easily accessible from below for fire fighting purposes.
§ 116.422 - Ceilings, linings, trim, interior finish and decorations.
(a) Ceilings, linings, and any furring incidental to their installation in control spaces, passageways, stairways, accommodation spaces and service spaces must be of noncombustible material in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant.
(b) Bulkheads, linings and ceilings may be covered by a combustible interior finish provided that such a finish is:
(1) Approved under § 164.012 in subchapter Q of this chapter, or other standard specified by the Commandant; or
(2) Listed by Underwriters Laboratories, does not exceed 2 millimeters (.075 inches) in thickness, and has a flame spread rating of not more than 20 and a smoke developed rating of not more than 10 when tested in accordance with ASTM E 84 (incorporated by reference, see § 114.600) or UL 723 by an independent laboratory.
(c) Bulkheads, linings, and ceilings in high risk accommodation spaces may have a combustible veneer trim and decorations that do not meet the requirements of paragraph (b) of this section, provided:
(1) The overall thickness of the combustible veneer does not exceed 2 millimeters (.075 inches); and
(2) The total volume of the combustible face trim, moldings, and decorations, including veneers, in any space does not exceed a volume equivalent to a 2.5 millimeter (0.1 inch) veneer on the combined area of the bulkheads and ceiling of the space.
(d) Combustible veneers may not be used in passageways, stairway enclosures or in low risk accommodation spaces. Combustible veneers, trim and decorations may not be used in or extend into hidden spaces such as behind linings or ceilings.
(e) Partial bulkheads or decks used to subdivide a space for artistic treatment and privacy must meet the requirements of Class C bulkheads.
(f) Nothing in this subpart may be construed as prohibiting the covering of any surface, including the surfaces of corridors, stairway enclosures, and hidden spaces, with a reasonable number of coats of paint or with a marine finish meeting the requirements of § 164.012 in subchapter Q of this chapter or other standard specified by the Commandant.
§ 116.423 - Furniture and furnishings.
(a) For the purpose of this subpart, rooms containing “fire resistant furnishings” are considered to be those in which:
(1) Furniture such as chairs, sofas, and similar items are tested and meet the requirements in UL 1056 “Fire Test of Upholstered Furniture,” or meet the requirements in § 72.05-55 in subchapter H of this chapter.
(2) Case furniture such as bookshelves, desks, cabinets, counters, beds, or other freestanding furniture are constructed in accordance with the requirements in § 72.05-55 (a)(1) in subchapter H of this chapter.
(3) Draperies, curtains and other similar furnishings and decorations are flame resistant. These materials must be tested in accordance with National Fire Protection Association (NFPA) 701 “Fire Tests for Flame Resistant Textiles and Films,” and must comply with either the small or large scale tests.
(4) Rugs and carpet may be used in addition to deck coverings. Rugs and carpets must be constructed of 100 percent wool or equivalent as determined by a flame spread rating not exceeding 75 and a smoke developed rating not exceeding 100 when tested according to ASTM E 84 (incorporated by reference, see § 114.600) or have a critical radiant flux not less than 0.8 watts per square centimeter (18 BTU's per hour per square inch) when tested according to ASTM E 648 (incorporated by reference, see § 114.600) “Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source,” and with a specific optical density not to exceed 450 in both flaming and nonflaming modes when tested according to ASTM E 662 (incorporated by reference, see § 114.600) “Specific Optical Density of Smoke generated by Solid Materials.” Also:
(i) Rugs and carpets shall not extend up bulkheads or vertical surfaces more than 10 centimeters (4 inches) above the deck.
(ii) Rugs and carpets are not permitted in machinery spaces, high risk service spaces, or areas where the spillage or leakage of flammable or combustible liquids is possible including areas immediately adjacent to bar service areas.
(b) Passageways and stairway enclosures shall contain only fire resistant furnishings. In addition, all upholstered chairs, sofas, etc., in these areas, shall be tested and meet the requirements in UL 1056 or have padding and upholstery of approved fire resistant materials.
§ 116.425 - Deck coverings.
(a) Except as provided in this section, deck coverings used for leveling or finishing purposes in control spaces, stairway enclosures, passageways, accommodation spaces and service spaces must be noncombustible.
(1) Materials approved under § 164.006 in subchapter Q of this chapter may be used in thicknesses not to exceed the approved thickness.
(2) Combustible deck leveling and finishing materials which are not approved under § 164.006 in subchapter Q of this chapter may be used in a thickness not to exceed 9.5 millimeters (.375 inches).
(b) [Reserved]
§ 116.427 - Fire load of accommodation and service spaces.
(a) Fire load calculations must be submitted by the owner for review to the Marine Safety Center when:
(1) A space is designated as a low risk accommodation space by the owner; or
(2) The cognizant OCMI determines, based on the quantity of combustibles, that the fire load present in a high risk accommodations space may exceed 37.5 kg (7.5 pounds) of combustibles per square meter (square foot) of deck area.
(b) When required under paragraph (a) of this section, fire load calculations must include all combustible construction and outfitting materials in addition to all loose or freestanding combustibles intended for use or stowage in the space. This includes but is not limited to: furniture, furnishings, carpets, rugs, combustible deck coverings, draperies, combustible interior finish, veneers, trim, and decorations, electrical cable insulation, plastic piping, light diffusers, mattresses, bedding, lifesaving equipment, and similar materials. The maximum fire load of a low risk accommodation or low risk service space as determined by fire load calculations must not exceed 15.0 kg (3 pounds) of combustibles per square meter (square foot) of deck area. The maximum fire load of a high risk accommodation space as determined by fire load calculations must not exceed 37.5 kg (7.5 pounds) of combustibles per square meter (square foot) of deck area.
§ 116.430 - Insulation other than for structural fire protection.
(a) Combustible insulation may be used for pipe and machinery covering or lagging within a machinery space, or used in an individual refrigerator box if the refrigerator box was purchased with the insulation already installed.
(b) Except as allowed by paragraph (a) of this section, any insulation installed for purposes other than structural fire protection and all material incidental to its installation must be noncombustible or approved under § 164.009 in subchapter Q of this chapter. Surfacing material applied to such insulation must be noncombustible or may meet the requirements of § 116.422(c) of this part.
§ 116.433 - Windows and air ports in fire control boundaries.
(a) Windows or air ports must be of tempered or laminated glass of at least 6.5 millimeters (0.25 inches) in thickness. The use of other glazing material such as polycarbonate sheets may be approved by the Commandant for specific installations.
(b) Windows or air ports in bulkheads adjacent to passageways must not extend below a point 910 millimeters (36 inches) above the deck unless storm rails, that are structurally independent of the glass, are fitted in the passageway.
(c) Windows or air ports in A-Class bulkheads must be fitted with frames of steel or equivalent material. Glazing beads or angles of steel or equivalent material must be installed to hold glass in place in windows or air ports in a fire control boundary in event of a fire if:
(1) Where a steel frame is used, it is not arranged to retain the glass in place; or
(2) A frame of aluminum or other material with low melting point is used.
(d) A window or air port that is adjacent to an embarkation station, escape route, or survival craft stowage must be:
(1) Of A-Class construction; or
(2) Fitted with shutters, operable from outside the space, of steel or equivalent material.
(e) A window installed in an internal fire control boundary must comply with the requirements of § 72.05-30 in subchapter H of this chapter, except that fire window frames and glazing material listed by Underwriters Laboratories may be used in B-Class bulkheads.
(f) Windows in doors in fire control boundaries must comply with the requirements of paragraphs (a) through (e) of this section.
(g) Windows complying with paragraphs (a) through (d) of this section may be installed in the external boundaries of stairtowers if there are no unprotected openings in the side of the vessel below the windows and if the windows are not exposed to any other parts of the vessel at an angle of less than 180 degrees.
§ 116.435 - Doors.
(a) A door, other than a watertight door, must meet the requirements of this section.
(b) A door in a fire control boundary must meet the following requirements:
(1) A door in an accommodation space, stairway, stairtower, or corridor must be oriented vertically;
(2) A door must be capable of operation from either side by one person;
(3) With the exception of staterooms, a door in an accommodation space, stairway, stairtower, passageway, or control space must open in the direction of escape, where practicable;
(4) Combustible veneers may be used on doors subject to the same restrictions as the fire control boundary in which the doors are fitted;
(5) Door frames must be of rigid construction and provide at least a 12.7 millimeter (0.5 inch) overlap at the sides and top, except:
(i) Double doors capable of independent operation and latching may have a clearance between the doors of not more than 3.2 millimeters (0.125 inches). However, if one door must always be closed first, means shall be provided to ensure that the doors close in the proper order; and
(ii) A double swing door, may have a clearance of not more than 3.2 millimeters (0.125 inches) at the top and sides;
(6) The maximum width of an individual door must not exceed 1200 millimeters (48 inches); and
(7) Hose ports, if fitted, must be in the lower corner of the door opposite the hinge so a hose may pass through the doorway when the door is open and still allow the door to close over the hose. The hose port should be approximately 152 millimeters (6 inches) square. A self-closing hinged or pivoted steel or equivalent material cover must be fitted in the opening.
(c) Doors in A-Class fire control boundaries must meet the following additional requirements:
(1) A door in a bulkhead required to be A-60, A-30, or A-15 Class must be of hollow steel or equivalent material construction, solidly filled with approved structural insulation, and capable of meeting the requirements of an A-15 Class bulkhead;
(2) A door in a bulkhead required to be A-0 Class must be of solid or hollow steel or equivalent material construction, and capable of meeting the requirements of an A-0 Class bulkhead;
(3) A door must have a latch with a minimum throw of 20 millimeters (0.75 inches);
(4) A door must not have vent grilles or louvers;
(5) A door must not be undercut more than 12.7 millimeters (0.5 inches) above the door sill or deck covering. Rugs and carpets must not pass through doorways, but linoleum and similar deck coverings may;
(6) A door in a stairtower, stairway, and main vertical zone bulkhead must meet the following additional requirements:
(i) A door must be of the self-closing type capable of closing against a 3.5 list of the vessel; and
(ii) Holdback hooks are not allowed. If installed, a hold back mechanism for a door must allow the door to be released:
(A) Locally:
(B) Upon a signal from a control space; and
(C) Upon disruption of the power system.
(7) Horizontal doors (doors installed in decks) are allowed only for access to spaces that are accessible only to crew members and are used only by crew members, subject to the following requirements:
(i) The door must be self-closing with a closure time of not less than 5 seconds and not more than 10 seconds, and be capable of closing against a 3.5 list of the vessel;
(ii) Holdback hooks are not allowed. If installed, a holdback mechanism for a door must allow the door to be released:
(A) Locally;
(B) Upon a signal from a control space; and
(C) Upon disruption of the power system.
(iii) The forces required to fully open the door must not exceed 17.8 Newtons (5 pounds) to release the latch, 44.5 Newtons (10 pounds) to set the door in motion, and 17.8 Newtons (5 pounds) to open the door to the width of the stairway; and
(iv) The door latch must be capable of keeping the door closed when a pressure of 0.07 kPa (0.01 psi) is applied to the underside of the door.
(8) Double swing doors must not be used in any bulkhead except between a food preparation space, such as a galley or pantry, and a messroom or dining room; and
(9) A door opening onto weather decks must meet the requirements of paragraphs (c)(1) or (c)(2) of this section or may be composed of hardwood of not less than 45 millimeters (1.75 inches) in thickness. In any case, no restriction as to the area of glass will be made for the doors insofar as this subpart is concerned. Only glass of the wire-inserted type may be fitted in the doors.
(10) Except as noted in paragraph (c)(9) of this section, doors may be fitted with not more than 0.065 square meters (100 square inches) of glass, which must be of the wire-inserted type.
(d) Doors in B-Class fire control boundaries must meet the following requirements in addition to those in paragraph (b) of this section:
(1) A door must be of solid or hollow steel or equivalent material construction, or must be of noncombustible material and be specifically approved by the Commandant;
(2) A door must have a latch with a minimum throw of 9.5 millimeters (0.375 inches); and
(3) A door must not be undercut more than 25 millimeters (1 inch) above the door sill or deck covering. Rugs and carpets must not pass through doorways but linoleum and similar coverings may.
(e) A door in a C-Class bulkhead must be of noncombustible material.
(f) A door used for decorative purposes, and that is not required to comply with paragraphs (b) through (e) of this section, must be constructed of noncombustible material or hardwood, must not interfere with the normal operation of the required doors, and must open in the same direction as the required doors. Decorative doors must not be used in stairways or stairtowers.
§ 116.438 - Stairtowers, stairways, ladders, and elevators.
(a) A vessel carrying more than 600 passengers or with overnight accommodations for more than 49 passengers must meet the requirements for stairways, ladders, and elevators in § 72.05-20 of this chapter.
(b) Materials. (1) Stairways, stairtowers, ladders, elevators, and landings must be designed with sufficient strength to sustain a load of 4.8 kPa (100 pounds per square foot) with a safety factor of 4, based on ultimate strength of the material;
(2) All stairways, ladders, elevators, and landings within machinery spaces and cargo holds must be composed of steel; and
(3) All stringers, treads, and all platforms and landings of all stairways shall be composed of steel, and risers must be of approved incombustible material, except that:
(i) Stairways, ladders, elevators, stringers, treads, platforms, and landings protected from potential fire exposure by being in either exterior locations or within protective enclosure bulkheads, decks and doors as described in the requirements of paragraph (j), may be constructed of approved incombustible material; and
(ii) All stairways, ladders, elevators, stringers, treads, platforms, and landings subject to potential fire exposure and not within a protective enclosure must be composed of steel unless their failure will not hinder fire fighter access or debarkation.
(c) A stairway or stairtower must be fitted with handrails on both sides at a vertical height above the tread at its nosing of between 840 and 910 millimeters (33 and 36 inches). A stairway or stairtower of more than 1,680 millimeters (66 inches) in width must also be fitted with a center handrail.
(d) A handrail fitted in a stairtower, stairway, landing, ladder, or elevator must be constructed of noncombustible material.
(e) A stairway or stairtower must be clear of all obstructions other than handrails.
(f) Curved, spiral, or winding stairways are permitted only with the specific approval of the Commandant.
(g) Differences in the depth of tread or height of riser of stairs in different flights of stairs in a stairway or stairtower must be minimized. In an individual flight of stairs in a stairway or stairtower, the depth of the tread and the height of riser shall not have a variance exceeding 5 millimeters (0.19685 inches).
(h) In a stairway or stairtower, the sum of the riser height and tread depth must be at least 432 millimeters (17 inches) and not more than 455 millimeters (18 inches). A stairway or stairtower having treads less than 254 millimeters (10 inches) in depth must have a nosing of 12.7 millimeters (0.5 inches) in width.
(i) Landings for stairways and stairtowers must meet the following requirements:
(1) A clear landing having an area at least equal to the square of the tread width must be provided at the top and bottom of each stairway; and
(2) Any interruption or change of direction in a stairway must be accomplished by means of an intermediate landing of a width and length at least equal to the tread width of the stairway.
(j) A stairway or stairtower must not have an angle of inclination from the horizontal of more than 40 degrees. However, stairways accessing spaces visited solely by crew members must not have an angle of inclination from the horizontal of more than 50 degrees. The Commanding Officer, Marine Safety Center may approve higher angles of inclination for spaces with severe space constraints.
(k) Where a continuous vertical deck penetration for a stairway or elevator exceeds one deck, the integrity of all decks must be assured by enclosure bulkheads and decks meeting the requirements of §§ 116.415(b) and 116.415(c) of this part. Doors meeting the requirements of §§ 116.435(b) and 116.435(c) of this part must be fitted in the enclosure at each deck serviced.
(l) Where a vertical deck penetration for a stairway or elevator involves only one deck, the integrity of the deck must be assured as required by paragraph (k) of this section. Alternatively the integrity of the deck may be maintained at one level only by means of bulkheads of the same fire control boundary rating as the deck penetrated. A door meeting the requirements of §§ 116.435(b) and 116.435(c) of this part must be fitted in the enclosure. In spaces containing a balcony, the integrity of the balcony deck in the way of stairways or elevators need not be assured. However, such stairways must not be considered to be a means of escape.
(m) Arrangements. (1) Each main vertical zone with more than two deck levels, each having enclosed or partially enclosed accommodation spaces, other than washroom or toilet spaces and open decks, must be served by at least one stairtower, so that a person may escape from any accommodation space or any other space where persons may be normally quartered or employed, to all other decks having any such spaces within the same main vertical zone, without coming out of the stairtower enclosure. Where a stairtower is accessible from two main vertical zones, it may be considered as the required stairtower for both main vertical zones provided all boundaries of the stairtower meet main vertical zone boundary requirements contained in § 116.415 of this part.
(2) Each stairtower must give access to an embarkation station or an area of refuge identified in the emergency escape plan required by § 116.520.
(3) Stairtowers must not give direct access to overnight accommodations or spaces of type 9, 10, 11, or 12.
(4) A stairtower is not required to extend below deck to serve spaces in which a fire is likely to originate if one of the means of escape is:
(i) A stairway that leads directly to a weather deck; or
(ii) A stairway leading to a stairtower enclosure that includes self closing fire doors at both the top and bottom; or
(iii) An alternative stairtower arrangement providing an equivalent level of safety is acceptable to the Commanding Officer, Marine Safety Center.
(5) The Commanding Officer, Marine Safety Center may accept other means of escape in combination with a stairtower provided the exits open directly to weather or through a main vertical zone bulkhead.
(6) For vessels in which a stairtower is not required, a stairway must provide a means of escape for each deck of the main vertical zone.
(n) The minimum tread width of a stairway or stairtower must be 8.4 millimeters (0.333 inches) for each person served, but must not be less than 910 millimeters (36 inches). However, in stairways accessing spaces utilized solely by crew members, the minimum tread width must be 8.4 millimeters (0.333 inches) for each person served, but not less than 710 millimeters (28 inches).
(1) The minimum tread width of a stairway or stairtower must be determined for each deck considering only those persons on that deck, except as provided in paragraph (n)(3) of this section. Once a minimum tread width has been established at any deck, it must not be decreased in the direction of escape.
(2) In determining the number of persons served, a space must be considered to contain at least the number of persons as follows:
(i) Passenger overnight accommodation spaces: Designed capacity;
(ii) Accommodation spaces having fixed seating for passengers: Maximum seating capacity;
(iii) Public spaces, including spaces such as casinos, restaurants, club rooms, and cinemas, and public accommodation spaces as defined in § 114.400 of this subchapter, except overnight accommodation spaces: One person for each 0.9 square meters (10 square feet) of deck area. In computing such deck area, the following areas must be excluded:
(A) Areas for which the number of persons permitted is determined using the fixed seating criterion;
(B) Obstructions, including stairway and elevator enclosures, elevated stages, bars, and cashier stands, but not including slot machines, tables, or other room furnishings;
(C) Toilets and washrooms;
(D) Interior passageways less than 850 millimeters (34 inches) wide and passageways on open deck less than 710 millimeters (28 inches) wide;
(E) Spaces necessary for handling lifesaving equipment, anchor handling equipment, or line handling gear, or in way of sail booms or running rigging; and
(F) Bow pulpits, swimming platforms, and areas that do not have a solid deck, such as netting on multi hull vessels;
(iv) Crew overnight accommodation spaces: Two-thirds designed capacity; and
(v) Work spaces: Occupancy under normal operating conditions.
(3) If a stairway forms part of a normal embarkation or debarkation route, or egress route to an area of refuge, the number of persons using the stairway for that purpose must be used in determining the minimum tread width. The Commanding Officer, Marine Safety Center, may approve a narrower stairway width if a narrower stairway will not unreasonably impede the flow of persons out of the space requiring egress or from an area of refuge to an embarkation station. Specific consideration can be given by the Marine Safety Center to the arrangement of landing area in excess of that required by paragraph (i) of this section when considering the approval of a narrower stairway width. However, the stairway width must be at least 910 millimeters (36 inches) unless the stairway is utilized solely by crew members, in which case the minimum tread width must be at least 710 millimeters (28 inches).
(4) If more than one stairtower serves a main vertical zone, the number of persons in that main vertical zone may be distributed among the stairtowers.
§ 116.439 - Balconies.
(a) An accommodation space containing a balcony must meet the requirements of this section.
(b) Each level of a space containing a balcony must have two independent means of escape that meet the requirements of § 116.500 of this part.
(c) For the purpose of main vertical zone bulkhead spacing requirements, the length of the space to which the balcony opens is considered to be increased by an amount equal to the gross area of the balcony divided by the average width of the space. If this equivalent main vertical zone length exceeds 40 meters (131 feet), the space must meet the requirements of paragraph (d) of this section. The actual length of the space may not exceed 40 meters (131 feet).
(d) If the equivalent main vertical zone length under paragraph (c) of this section exceeds 40 meters (131 feet), both decks connected by the balcony must be protected with an automatic sprinkler system meeting NFPA 13.
(e) If the unobstructed balcony opening area is less than 93 square meters (1,000 square feet), the opening must be protected in accordance with NFPA 13 or other standard specified by the Commandant. The horizontal projection area of stairs, escalators, statues, or other obstructions must be subtracted from the total balcony opening area for purposes of computation of unobstructed balcony opening area.
§ 116.440 - Atriums.
(a) The atrium opening area must be a minimum of 93 square meters (1,000 square feet) or 20 percent of the gross deck area of the largest deck within the accommodation space containing the atrium, whichever is smaller.
(1) Each side of an atrium opening must be a minimum of 6.1 meters (20 feet) in length. If the opening is circular or ellipsoid, it must measure at least 6.1 meters (20 feet) across in any direction.
(2) Any deck opening within an atrium must fit wholly within the horizontal projection of any deck opening of an upper deck.
(3) The horizontal projection area of stairs, escalators, statues, etc. within the atrium must not be included for purposes of computation of atrium opening area.
(b) The entire main vertical zone containing an atrium must be protected throughout with a smoke detection system of an approved type which is installed in accordance with § 76.27 in subchapter H of this chapter. However, on vessels with no overnight passenger accommodations, smoke detectors may be omitted from the accommodation space containing the atrium.
(c) The entire main vertical zone containing an atrium must be protected with an automatic sprinkler system meeting NFPA 13 (incorporated by reference, see § 114.600).
(d) The atrium must be provided with a smoke extraction system that complies with either:
(1) The smoke extraction system must be capable of exhausting the entire volume of the space within 10 minutes. The smoke extraction system must be capable of being activated by both the smoke detection system and by manual control, and designed with sufficient plenum air openings to prevent excessive negative air pressure in the atrium; or,
(2) The smoke extraction system may be designed in accordance with the principles of NFPA 92B “Smoke Management Systems in Malls, Atria, and Large Areas.”
(e) Each level within the atrium must have two independent means of escape that comply with § 116.500 of this part. At least one of the means of escape must be a stairtower.