§ 112.43-1 - Switches.
An emergency lighting system must not have a switch, except:
(a) In a distribution panel;
(b) As required in § 112.43-7; or
(c) In a circuit that serves a hazardous space such as a paint room or cargo handling room if the switch is located outside of the hazardous location.
§ 112.43-5 - Controls on island type vessels.
On an island type vessel, such as a containership, emergency lights for illumination of survival craft launching operations must be controlled from a central location within the island nearest the launching operations or from the navigating bridge.
§ 112.43-7 - Navigating bridge distribution panel.
(a) Except as allowed in paragraph (b) of this section, the following emergency lights must be supplied from a distribution panel on the navigating bridge:
(1) Navigation lights not supplied by the navigation light indicator panel.
(2) Lights for survival craft launching operations under § 111.75-16, except as allowed in § 112.43-5.
(3) Signaling lights.
(4) Emergency lights:
(i) On open decks;
(ii) On the navigating bridge;
(iii) In the chartroom;
(iv) In the fire control room; and
(v) For navigation equipment.
(b) On a mobile offshore drilling unit, the distribution panel required in paragraph (a) of this section must be in the control room.
(c) Each distribution panel required in paragraphs (a) and (b) of this section must have a fused switch or circuit breaker for each branch circuit.
§ 112.43-9 - Signaling lights.
Each signaling light must be supplied by a branch circuit that supplies no other equipment.
§ 112.43-11 - Illumination for launching operations.
Branch circuits supplying power to lights for survival craft launching operations must supply no other equipment and meet § 111.75-16 of this chapter.
§ 112.43-13 - [Reserved]
§ 112.43-15 - Emergency lighting feeders.
For a vessel with fire bulkheads forming fire zones, at least one emergency lighting feeder must supply only the emergency lights between two adjacent main vertical fire zone bulkheads. The emergency lighting feeder must be separated as widely as practicable from any general lighting feeder supplying the same space.