Collapse to view only § 111.25-1 - General requirements.
§ 111.25-1 - General requirements.
The requirements for generators contained in § 111.12-5 apply to motors.
§ 111.25-5 - [Reserved]
§ 111.25-15 - Duty cycle.
Each motor must be rated for continuous duty, except a motor for an application listed in Table 111.25-15 or a similar duty must meet the minimum short-time rating stated in the table.
Table 111.25-15
Application of motor | Minimum short-time rating of motor, in hours | Deck winch and direct acting capstan | Half. | Deck winch with hydraulic transmission | Continuous at no load followed by 1/2 hr. at full load. | Direct acting windlass | One fourth. | Windlass with hydraulic transmission | Half hour idle pump operation, followed by 1/4 hr. full load operation. | Steering gear, direct acting | One. | Steering gear, indirect drive | Continuous operation at 15 pct. load followed by 1 hr. at full load. | Watertight door operators | 1/12. | Boat winches | 1/12. |
---|