Collapse to view only § 430.11 - Specialized definitions.

§ 430.10 - Applicability; description of the dissolving kraft subcategory.

The provisions of this subpart apply to discharges resulting from the production of dissolving pulp at kraft mills.

§ 430.11 - Specialized definitions.

For the purpose of this subpart, the general definitions, abbreviations, and methods of analysis set forth in 40 CFR part 401 and § 430.01 of this part shall apply to this subpart.

§ 430.12 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

(a) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT), except that non-continuous dischargers shall not be subject to the maximum day and average of 30 consecutive days limitations but shall be subject to annual average effluent limitations:

Subpart A

[BPT effluent limitations]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers Maximum for any 1 day Average of daily values for 30 consecutive days BOD523.612.256.88 TSS37.320.0511.02 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

(b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, resulting from the use of wet barking operations, which may be discharged by a point source subject to the provisions of this subpart. These limitations are in addition to the limitations set forth in paragraph (a) of this section and shall be calculated using the proportion of the mill's total production due to use of logs which are subject to such operations. Non-continuous dischargers shall not be subject to the maximum day and average of 30 consecutive days limitations, but shall be subject to annual average effluent limitations:

Subpart A

[BPT effluent limitations]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual average) Maximum for any 1 day Average of daily values for 30 consecutive days BOD53.21.70.95 TSS6.93.752.0 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

(c) The following limitations establish the quantity or quality of pollutants or pollutant parameters, controlled by this section, resulting from the use of log washing or chip washing operations, which may be discharged by a point source subject to the provisions of this subpart. These limitations are in addition to the limitations set forth in paragraph (a) of this section and shall be calculated using the proportion of the mill's total production due to use of logs and/or chips which are subject to such operations. Non-continuous dischargers shall not be subject to the maximum day and average of 30 consecutive days limitations, but shall be subject to the annual average effluent limitations:

Subpart A

[BPT effluent limitations]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD50.350.20.1 TSS0.700.40.2 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

(d) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, resulting from the use of log flumes or log ponds, which may be discharged by a point source subject to the provisions of this subpart. These limitations are in addition to the limitations set forth in paragraph (a) of this section and shall be calculated using the proportion of the mill's total production due to use of logs which are subject to such operations. Non-continuous dischargers shall not be subject to the maximum day and average of 30 consecutive days limitations but shall be subject to the annual average effluent limitations:

Subpart A

[BPT effluent limitations]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD50.60.350.2 TSS1.450.80.4 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

§ 430.13 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in 40 CFR 401.16) in § 430.12 of this subpart for the best practicable control technology currently available (BPT).

§ 430.14 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart where chlorophenolic-containing biocides are used must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT). Non-continuous dischargers shall not be subject to the maximum day mass limitations in kg/kkg (lb/1000 lb) but shall be subject to concentration limitations. Concentration limitations are only applicable to non-continuous dischargers. Permittees not using chlorophenolic-containing biocides must certify to the permit-issuing authority that they are not using these biocides:

Subpart A

[BAT effluent limitations]

Pollutant or pollutant property Maximum for any 1 day Kg/kkg (or pounds per 1,000 lb) of product Milligrams/liter Pentachlorophenol0.0025(0.011)(55.1)/y Trichlorophenol0.016(0.068)(55.1)/y y = wastewater discharged in kgal per ton of product.

§ 430.15 - New source performance standards (NSPS).

Any new source subject to this subpart must achieve the following new source performance standards (NSPS), except that non-continuous dischargers shall not be subject to the maximum day and average of 30 consecutive days effluent limitations for BOD5 and TSS, but shall be subject to annual average effluent limitations. Also, for non-continuous dischargers, concentration limitations (mg/l) shall apply, where provided. Concentration limitations will only apply to non-continuous dischargers. Only facilities where chlorophenolic-containing biocides are used shall be subject to pentachlorophenol and trichlorophenol limitations. Permittees not using chlorophenolic-containing biocides must certify to the permit-issuing authority that they are not using these biocides:

Subpart A

[NSPS]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD515.68.44.4 TSS27.314.37.5 pH( 1)( 1)( 1)
Maximum for any 1 day Kg/kkg (or pounds per 1,000 lb) of product Milligrams/liter Pentachlorophenol0.0025(0.012)(50.7)/y Trichlorophenol0.016 (0.074)(50.7)/y y = wastewater discharged in kgal per ton at all times.

1 Within the range of 5.0 to 9.0 at all times.

§ 430.16 - Pretreatment standards for existing sources (PSES).

Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart that introduces pollutants into a publicly owned treatment works must: comply with 40 CFR part 403; and achieve the following pretreatment standards for existing sources (PSES) if it uses chlorophenolic-containing biocides. Permittees not using chlorophenolic-containing biocides must certify to the permit-issuing authority that they are not using these biocides. PSES must be attained on or before July 1, 1984:

Subpart A

[PSES]

Pollutant or pollutant property Maximum for any 1 day Milligrams/liter (mg/l) Kg/kkg (or pounds per 1,000 lb) of product aPentachlorophenol(0.011)(55.1)/y0.0025 Trichlorophenol(0.082)(55.1)/y0.019 y = wastewater discharged in kgal per ton of product.

a The following equivalent mass limitations are provided as guidance in cases when POTWs find it necessary to impose mass effluent limitations.

§ 430.17 - Pretreatment standards for new sources (PSNS).

Except as provided in 40 CFR 403.7, any new source subject to this subpart that introduces pollutants into a publicly owned treatment works must: comply with 40 CFR part 403; and achieve the following pretreatment standards for new sources (PSNS) if it uses chlorophenolic-containing biocides. Permittees not using chlorophenolic-containing biocides must certify to the permit-issuing authority that they are not using these biocides:

Subpart A

[PSNS]

Pollutant or pollutant property Maximum for any 1 day Milligrams/liter (mg/l) Kg/kkg (or pounds per 1,000 lb) of product aPentachlorophenol(0.012)(50.7)/y0.0025 Trichlorophenol(0.089)(50.7)/y0.019 y = wastewater discharged in kgal per ton of product.

a The following equivalent mass limitations are provided as guidance in cases when POTWs find it necessary to impose mass effluent limitations.