Collapse to view only § 421.140 - Applicability: Description of the primary antimony subcategory.
- § 421.140 - Applicability: Description of the primary antimony subcategory.
- § 421.141 - Specialized definitions.
- § 421.142 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
- § 421.143 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
- § 421.144 - Standards of performance for new sources.
- § 421.145 - [Reserved]
- § 421.146 - Pretreatment standards for new sources.
- § 421.147 - [Reserved]
§ 421.140 - Applicability: Description of the primary antimony subcategory.
The provisions of this subpart are applicable to discharges resulting from the production of antimony at primary antimony facilities.
§ 421.141 - Specialized definitions.
For the purpose of this subpart the general definitions, abbreviations, and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.
§ 421.142 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available:
(a) Sodium Antimonate Autoclave Wastewater.
BPT Limitations for the Primary Antimony Subcategory
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average | mg/kg (pounds per million pounds) of antimony contained in sodium antimonate product | Antimony | 44.840 | 20.000 | Arsenic | 32.650 | 14.530 | Mercury | 3.906 | 1.562 | Total suspended solids | 640.600 | 304.700 | pH | ( 1) | ( 1) |
---|
1 Within the range of 7.5 to 10.0 at all times.
(b) Fouled anolyte.
BPT Limitations for the Primary Antimony Subcategory
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average | mg/kg (pounds per million pounds) of antimony metal produced by electrowinning | Antimony | 44.840 | 20.000 | Arsenic | 32.650 | 14.530 | Mercury | 3.906 | 1.562 | Total suspended solids | 640.600 | 304.700 | pH | ( 1) | ( 1) |
---|
1 Within the range of 7.5 to 10.0 at all times.
(c) Cathode Antimony Wash Water.
BPT Limitations for the Primary Antimony Subcategory
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average | mg/kg (pounds per million pounds) of antimony metal produced by electrowinning | Antimony | 89.680 | 40.000 | Arsenic | 65.310 | 29.060 | Mercury | 7.812 | 3.125 | Total suspended solids | 1,281.000 | 609.300 | pH | ( 1) | ( 1) |
---|
1 Within the range of 7.5 to 10.0 at all times.
§ 421.143 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable:
(a) Sodium Antimonate Autoclave Wastewater.
BAT Limitations for the Primary Antimony Subcategory
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average | mg/kg (pounds per million pounds) of antimony contained in sodium antimonate product | Antimony | 30.150 | 13.440 | Arsenic | 21.720 | 9.687 | Mercury | 2.344 | 0.937 |
---|
(b) Fouled Anolyte.
BAT Limitations for the Primary Antimony Subcategory
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average | mg/kg pounds per million pounds of antimony metal produced by electrowinning | Antimony | 30.150 | 13.440 | Arsenic | 21.720 | 9.687 | Mercury | 2.344 | 0.937 |
---|
(c) Cathode Antimony Wash Water
BAT Limitations for the Primary Antimony Subcategory
Pollutant of pollutant property | Maximum for any 1 day | Maximum for monthly average | mg/kg (pounds per million pounds) of antimony metal produced by electrowinning | Antimony | 60.310 | 26.870 | Arsenic | 43.430 | 19.370 | Mercury | 4.687 | 1.875 |
---|
§ 421.144 - Standards of performance for new sources.
Any new source subject to this subpart shall achieve the following new source performance standards:
(a) Sodium Antimonate Autoclave Wastewater.
NSPS for the Primary Antimony Subcategory
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average | mg/kg (pounds per million pounds) of antimony contained in sodium antimonate product | Antimony | 30.150 | 13.440 | Arsenic | 21.720 | 9.687 | Mercury | 2.344 | 0.937 | Total suspended solids | 234.400 | 187.500 | pH | ( 1) | ( 1) |
---|
1 Within the range of 7.5 to 10.0 at all times.
(b) Fouled Anolyte.
NSPS for the Primary Antimony Subcategory
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average | mg/kg (pounds per million pounds) of antimony metal produced by electrowinning | Antimony | 30.150 | 13.440 | Arsenic | 21.720 | 9.687 | Mercury | 2.344 | 0.937 | Total suspended solids | 234.400 | 187.500 | pH | ( 1) | ( 1) |
---|
1 Within the range of 7.5 to 10.0 at all times.
(c) Cathode Antimony Wash Water.
NSPS for the Primary Antimony Subcategory
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average | mg/kg (pounds per million pounds) of antimony metal produced by electrowinning | Antimony | 60.310 | 26.870 | Arsenic | 43.430 | 19.370 | Mercury | 4.687 | 1.875 | Total suspended solids | 468.700 | 375.000 | pH | ( 1) | ( 1) |
---|
1 Within the range of 7.5 to 10.0 at all times.
§ 421.145 - [Reserved]
§ 421.146 - Pretreatment standards for new sources.
Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources. The mass of wastewater pollutants in primary antimony process wastewater introduced into a POTW shall not exceed the following values:
(a) Sodium Antimonate Autoclave Wastewater.
PSNS for the Primary Antimony Subcategory
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average | mg/kg (pounds per million pounds) of antimony contained in sodium antimonate product | Antimony | 30.150 | 13.440 | Arsenic | 21.720 | 9.687 | Mercury | 2.344 | 0.937 |
---|
(b) Fouled Anolyte.
PSNS for the Primary Antimony Subcategory
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average | mg/kg (pounds per million pounds) of antimony metal produced by electrowinning | Antimony | 30.150 | 13.440 | Arsenic | 21.720 | 9.687 | Mercury | 2.344 | 0.937 |
---|
(c) Cathode Antimony Washwater.
PSNS for the Primary Antimony Subcategory
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average | mg/kg (pounds per million pounds) of antimony metal produced by electrowinning | Antimony | 60.310 | 26.870 | Arsenic | 43.430 | 19.370 | Mercury | 4.687 | 1.875 |
---|