Collapse to view only § 75.1712-4 - Waiver of surface facilities requirements.
- § 75.1700 - Oil and gas wells.
- § 75.1702 - Smoking; prohibition.
- § 75.1702-1 - Smoking programs.
- § 75.1703 - Portable electric lamps.
- § 75.1703-1 - Permissible lamps.
- § 75.1707-1 - New working section.
- § 75.1708 - Surface structures, fireproofing.
- § 75.1708-1 - Surface structures; fireproof construction.
- § 75.1709 - Accumulations of methane and coal dust on surface coal-handling facilities.
- § 75.1710 - Canopies or cabs; diesel-powered and electric face equipment.
- § 75.1710-1 - Canopies or cabs; self-propelled diesel-powered and electric face equipment; installation requirements.
- § 75.1711 - Sealing of mines.
- § 75.1711-1 - Sealing of shaft openings.
- § 75.1711-2 - Sealing of slope or drift openings.
- § 75.1711-3 - Openings of active mines.
- § 75.1712 - Bath houses and toilet facilities.
- § 75.1712-1 - Availability of surface bathing facilities; change rooms; and sanitary facilities.
- § 75.1712-2 - Location of surface facilities.
- § 75.1712-3 - Minimum requirements of surface bathing facilities, change rooms, and sanitary toilet facilities.
- § 75.1712-4 - Waiver of surface facilities requirements.
- § 75.1712-5 - Application for waiver of surface facilities.
- § 75.1712-6 - Underground sanitary facilities; installation and maintenance.
- § 75.1712-7 - Underground sanitary facilities; waiver of requirements.
- § 75.1712-8 - Application for waiver of location requirements for underground sanitary facilities.
- § 75.1712-9 - Issuance of waivers.
- § 75.1712-10 - Underground sanitary facilities; maintenance.
- § 75.1713 - Emergency medical assistance; first-aid.
- § 75.1713-1 - Arrangements for emergency medical assistance and transportation for injured persons; agreements; reporting requirements; posting requirements.
- § 75.1713-2 - Emergency communications; requirements.
- § 75.1713-3 - First-Aid training; supervisory employees.
- § 75.1713-4 - First-aid training program; availability of instruction to all miners.
- § 75.1713-5 - First-aid training program; retraining of supervisory employees; availability to all miners.
- § 75.1713-6 - First-aid training program; minimum requirements.
- § 75.1713-7 - First-aid equipment; location; minimum requirements.
- § 75.1714 - Availability of approved self-rescue devices; instruction in use and location.
- § 75.1714-1 - Approved self-rescue devices.
- § 75.1714-2 - Self-rescue devices; use and location requirements.
- § 75.1714-3 - Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.
- § 75.1714-4 - Additional self-contained self-rescuers (SCSRs).
- § 75.1714-5 - Map locations of self-contained self-rescuers (SCSR).
- § 75.1714-6 - Emergency tethers.
- § 75.1714-7 - Multi-gas detectors.
- § 75.1714-8 - Reporting SCSR inventory and malfunctions; retention of SCSRs.
- § 75.1715 - Identification check system.
- § 75.1716 - Operations under water.
- § 75.1716-1 - Operations under water; notification by operator.
- § 75.1716-2 - Permit required.
- § 75.1716-3 - Applications for permits.
- § 75.1716-4 - Issuance of permits.
- § 75.1717 - Exemptions.
- § 75.1718 - Drinking water.
- § 75.1718-1 - Drinking water; quality.
- § 75.1719 - Illumination; purpose and scope of §through 75.1719-4; time for compliance.
- § 75.1719-1 - Illumination in working places.
- § 75.1719-2 - Lighting fixtures; requirements.
- § 75.1719-3 - Methods of measurement; light measuring instruments.
- § 75.1719-4 - Mining machines, cap lamps; requirements.
- § 75.1720 - Protective clothing; requirements.
- § 75.1720-1 - Distinctively colored hard hats, or hard caps; identification for newly employed, inexperienced miners.
- § 75.1721 - Opening of new underground coal mines, or reopening and reactivating of abandoned or deactivated coal mines, notification by the operator; requirements.
- § 75.1722 - Mechanical equipment guards.
- § 75.1723 - Stationary grinding machines; protective devices.
- § 75.1724 - Hand-held power tools; safety devices.
- § 75.1725 - Machinery and equipment; operation and maintenance.
- § 75.1726 - Performing work from a raised position; safeguards.
- § 75.1727 - Drive belts.
- § 75.1728 - Power-driven pulleys.
- § 75.1729 - Welding operations.
- § 75.1730 - Compressed air; general; compressed air systems.
- § 75.1731 - Maintenance of belt conveyors and belt conveyor entries.
- § 75.1732 - Proximity detection systems.
§ 75.1700 - Oil and gas wells.
Each operator of a coal mine shall take reasonable measures to locate oil and gas wells penetrating coalbeds or any underground area of a coal mine. When located, such operator shall establish and maintain barriers around such oil and gas wells in accordance with State laws and regulations, except that such barriers shall not be less than 300 feet in diameter, unless the Secretary or his authorized representative permits a lesser barrier consistent with the applicable State laws and regulations where such lesser barrier will be adequate to protect against hazards from such wells to the miners in such mine, or unless the Secretary or his authorized representative requires a greater barrier where the depth of the mine, other geologic conditions, or other factors warrant such a greater barrier.
§ 75.1702 - Smoking; prohibition.
No person shall smoke, carry smoking materials, matches, or lighters underground, or smoke in or around oil houses, explosives magazines, or other surface areas where such practice may cause a fire or explosion. The operator shall institute a program, approved by the Secretary, to insure that any person entering the underground area of the mine does not carry smoking materials, matches, or lighters.
§ 75.1702-1 - Smoking programs.
Programs required under § 75.1702 shall be submitted to the Coal Mine Safety District Manager for approval on or before May 30, 1970.
§ 75.1703 - Portable electric lamps.
Persons underground shall use only permissible electric lamps approved by the Secretary for portable illumination. No open flame shall be permitted in the underground area of any coal mine, except as permitted under § 75.1106.
§ 75.1703-1 - Permissible lamps.
Lamps approved by the Bureau of Mines or the Mine Safety and Health Administration under Part 19 or Part 20 of this chapter (Bureau of Mines Schedule 6D and Schedule 10C) are approved lamps for the purposes of § 75.1703.
§ 75.1707-1 - New working section.
The term “new working section” as used in § 75.1707 means any extension of the belt or trolley haulage system in main, cross, and room entries necessary for the development of the mine on and after March 30, 1970. Room entries being developed as of March 30, 1970, with certified stop line limitations as shown on the mine map and retreating panels shall not be considered as new working sections.
§ 75.1708 - Surface structures, fireproofing.
After March 30, 1970, all structures erected on the surface within 100 feet of any mine opening shall be of fireproof construction. Unless structures existing on or prior to such date which are located within 100 feet of any mine opening are of such construction, fire doors shall be erected at effective points in mine openings to prevent smoke or fire from outside sources endangering miners underground. These doors shall be tested at least monthly to insure effective operation. A record of such tests shall be kept in an area on the surface of the mine chosen by the operator to minimize the danger of destruction by fire or other hazard and shall be available for inspection by interested persons.
§ 75.1708-1 - Surface structures; fireproof construction.
Structures of fireproof construction is interpreted to mean structures with fireproof exterior surfaces.
§ 75.1709 - Accumulations of methane and coal dust on surface coal-handling facilities.
Adequate measures shall be taken to prevent methane and coal dust from accumulating in excessive concentrations in or on surface coal-handling facilities, but in no event shall methane be permitted to accumulate in concentrations in or on surface coal-handling facilities in excess of limits established for methane by the Secretary on and after March 30, 1971. Where coal is dumped at or near air-intake openings, provisions shall be made to avoid dust from entering the mine.
§ 75.1710 - Canopies or cabs; diesel-powered and electric face equipment.
In any coal mine where the height of the coalbed permits, an authorized representative of the Secretary may require that diesel-powered and electric face equipment, including shuttle cars, be provided with substantially constructed canopies or cabs to protect the miners operating such equipment from roof falls and from rib and face rolls.
§ 75.1710-1 - Canopies or cabs; self-propelled diesel-powered and electric face equipment; installation requirements.
(a) Except as provided in paragraph (f) of this section, all self-propelled diesel-powered and electric face equipment, including shuttle cars, which is employed in the active workings of each underground coal mine on and after January 1, 1973, shall, in accordance with the schedule of time specified in paragraphs (a) (1), (2), (3), (4), (5), and (6) of this section, be equipped with substantially constructed canopies or cabs, located and installed in such a manner that when the operator is at the operating controls of such equipment he shall be protected from falls of roof, face, or rib, or from rib and face rolls. The requirements of this paragraph (a) shall be met as follows:
(1) On and after January 1, 1974, in coal mines having mining heights of 72 inches or more;
(2) On and after July 1, 1974, in coal mines having mining heights of 60 inches or more, but less than 72 inches;
(3) On and after January 1, 1975, in coal mines having mining heights of 48 inches or more, but less than 60 inches;
(4) On and after July 1, 1975, in coal mines having mining heights of 36 inches or more, but less than 48 inches;
(5)(i) On and after January 1, 1976, in coal mines having mining heights of 30 inches or more, but less than 36 inches,
(ii) On and after July 1, 1977, in coal mines having mining heights of 24 inches or more, but less than 30 inches, and
(6) On and after July 1, 1978, in coal mines having mining heights of less than 24 inches.
(b)(1) For purposes of this section, a canopy means a structure which provides overhead protection against falls of roof.
(2) For purposes of this section, a cab means a structure which provides overhead and lateral protection against falls of roof, rib, and face, or rib and face rolls.
(c) In determining whether to install substantially constructed canopies as opposed to substantially constructed cabs, the operator shall consider and take into account the following factors:
(1) The mining method used;
(2) Physical limitations, including but not limited to the dip of the coalbed, and roof, rib, and face conditions;
(3) Previous accident experience, if any, caused by falls of roof, rib, and face, or rib and face rolls;
(4) Overhead protection, such as that afforded by a substantially constructed canopy, against falls of roof will always be required; and
(5) Lateral protection, such as that afforded by a substantially constructed cab, may also be necessary where the occurrence of falls of rib and face, or rib and face rolls is likely.
(d) For purposes of this section, a canopy or cab will be considered to be substantially constructed if a registered engineer certifies that such canopy or cab has the minimum structural capacity to support elastically:
(1) A dead weight load of 18,000 pounds, or
(2) 15 p.s.i. distributed uniformly over the plan view area of the structure, whichever is lesser.
(e) Evidence of the certification required by paragraph (d) of this section shall be furnished by attaching a plate, label, or other appropriate marking to the canopy or cab for which certification has been made, stating that such canopy or cab meets the minimum requirements for structural capacity set forth in paragraph (d) of this section. Written evidence of such certification shall also be retained by the operator, and shall be made available to an authorized representative of the Secretary upon request. Written evidence of certification may consist of the report of the registered engineer who certified the canopy or cab, or of information from the manufacturer of the canopy or cab stating that a registered engineer has certified that the canopy or cab meets the minimum requirements for structural capacity set forth in paragraph (d) of this section.
(f) An operator may apply to the Director of Technical Support, Mine Safety and Health Administration, Department of Labor, 201 12th Street South, Arlington, VA 22202-5452, for approval of the installation of devices to be used in lieu of substantially constructed canopies or cabs on self-propelled diesel-powered and electric face equipment. The Director of Technical Support may approve such devices if he determines that the use thereof will afford the equipment operator no less than the same measure of protection from falls of roof, face, or rib, or from rib and face rolls as would a substantially constructed canopy or cab meeting the requirements of this section.
§ 75.1711 - Sealing of mines.
On or after March 30, 1970, the opening of any coal mine that is declared inactive by the operator, or is permanently closed, or abandoned for more than 90 days, shall be sealed by the operator in a manner prescribed by the Secretary. Openings of all other mines shall be adequately protected in a manner prescribed by the Secretary to prevent entrance by unauthorized persons.
§ 75.1711-1 - Sealing of shaft openings.
Shaft openings required to be sealed under § 75.1711 shall be effectively capped or filled. Filling shall be for the entire depth of the shaft and, for the first 50 feet from the bottom of the coalbed, the fill shall consist of incombustible material. Caps consisting of a 6-inch thick concrete cap or other equivalent means may be used for sealing. Caps shall be equipped with a vent pipe at least 2 inches in diameter extending for a distance of at least 15 feet above the surface of the shaft.
§ 75.1711-2 - Sealing of slope or drift openings.
Slope or drift openings required to be sealed under § 75.1711 shall be sealed with solid, substantial, incombustible material, such as concrete blocks, bricks or tile, or shall be completely filled with incombustible material for a distance of at least 25 feet into such openings.
§ 75.1711-3 - Openings of active mines.
The openings of all mines not declared by the operator, to be inactive, permanently closed, or abandoned for less than 90 days shall be adequately fenced or posted with conspicuous signs prohibiting the entrance of unauthorized persons.
§ 75.1712 - Bath houses and toilet facilities.
The Secretary may require any operator to provide adequate facilities for the miners to change from the clothes worn underground, to provide for the storing of such clothes from shift to shift, and to provide sanitary and bathing facilities. Sanitary toilet facilities shall be provided in the active workings of the mine when such surface facilities are not readily accessible to the active workings.
§ 75.1712-1 - Availability of surface bathing facilities; change rooms; and sanitary facilities.
Except where a waiver has been granted pursuant to the provisions of § 75.1712-4, each operator of an underground coal mine shall on and after December 30, 1970, provide bathing facilities, clothing change rooms, and sanitary facilities, as hereinafter prescribed, for the use of the miners at the mine.
§ 75.1712-2 - Location of surface facilities.
Bathhouses, change rooms, and sanitary toilet facilities shall be in a location convenient for the use of the miners. Where such facilities are designed to serve more than one mine, they shall be centrally located so as to be as convenient for the use of the miners in all the mines served by such facilities.
§ 75.1712-3 - Minimum requirements of surface bathing facilities, change rooms, and sanitary toilet facilities.
(a) All bathing facilities, change rooms, and sanitary toilet facilities shall be provided with adequate light, heat, and ventilation so as to maintain a comfortable air temperature and to minimize the accumulation of moisture and odors, and such facilities shall be maintained in a clean and sanitary condition.
(b) Bathing facilities, change rooms, and sanitary toilet facilities shall be constructed and equipped so as to comply with applicable State and local building codes: Provided, however, That where no State or local building codes apply to such facilities, or where no State or local building codes exist, such facilities shall be constructed and equipped so as to meet the minimum construction requirements of the National Building Code; and the minimum plumbing requirements of the U.S.A. Standard Plumbing Code, ASA A40.8-1955.
(c) In addition to the minimum requirements specified in paragraphs (a) and (b) of this § 75.1712-3, facilities maintained in accordance with § 75.1712-1 shall include the following:
(1) Bathing facilities. (i) Showers shall be provided with both hot and cold water.
(ii) At least one shower head shall be provided where five or less miners use such showers.
(iii) Where five or more miners use such showers, sufficient showers shall be furnished to provide approximately one shower head for each five miners.
(iv) A suitable cleansing agent shall be provided for use at each shower.
(2) Sanitary toilet facilities. (i) At least one sanitary flush toilet shall be provided where 10 or less miners use such facilities.
(ii) Where 10 or more miners use such sanitary toilet facilities, sufficient toilets shall be furnished to provide approximately one sanitary flush toilet for each 10 miners.
(iii) Where 30 or more miners use sanitary toilet facilities, one urinal may be substituted for one sanitary flush toilet, however, where such substitutions are made they shall not reduce the number of toilets below a ratio of two toilets to one urinal.
(iv) An adequate supply of toilet paper shall be provided with each toilet.
(v) Adequate handwashing facilities or hand lavatories shall be provided in or adjacent to each toilet facility.
(3) Change rooms. (i) Individual clothes storage containers or lockers shall be provided for storage of miners clothing and other incidental personal belongings during and between shifts.
(ii) Change rooms shall be provided with ample space to permit the use of such facilities by all miners changing clothes prior to and after each shift.
§ 75.1712-4 - Waiver of surface facilities requirements.
The Coal Mine Safety District Manager for the district in which the mine is located may, upon written application by the operator, waive any or all of the requirements of §§ 75.1712-1 through 75.1712-3 if he determines that the operator of the mine cannot or need not meet any part or all of such requirements, and, upon issuance of such waiver, he shall set forth the facilities which will not be required and the specific reason or reasons for such waiver.
§ 75.1712-5 - Application for waiver of surface facilities.
Applications for waivers of the requirements of §§ 75.1712-1 through 75.1712-3 shall be filed with the Coal Mine Safety District Manager and shall contain the following information:
(a) The name and address of the mine operator;
(b) The name and location of the mine;
(c) A statement explaining why, in the opinion of the operator, the installation or maintenance of the facilities is impractical or unnecessary.
§ 75.1712-6 - Underground sanitary facilities; installation and maintenance.
(a) Except as provided in § 75.1712-7, each operator of an underground coal mine shall provide and maintain one sanitary toilet in a dry location under protected roof, within 500 feet of each working place in the mine where miners are regularly employed during the mining cycle. A single sanitary toilet may serve two or more working places in the same mine, if it is located within 500 feet of each such working place.
(b) Sanitary toilets shall have an attached toilet seat with a hinged lid and a toilet paper holder together with an adequate supply of toilet tissue, except that a toilet paper holder is not required for an unenclosed toilet facility.
(c) Only flush or nonflush chemical or biological toilets, sealed bag toilets, and vault toilets meet the requirements of this section. Privies and combustion or incinerating toilets are prohibited underground.
§ 75.1712-7 - Underground sanitary facilities; waiver of requirements.
If it has been determined by the Coal Mine Safety District Manager for the district in which the mine is located that sanitary toilets cannot be provided and maintained within 500 feet of a working place because of the thickness of the coal seam or because of any other physical restriction in the underground workings, he may, upon written application by the operator, waive the location requirements for underground sanitary facilities with respect to such working place.
§ 75.1712-8 - Application for waiver of location requirements for underground sanitary facilities.
Applications for waivers of the location requirements of § 75.1712-6 shall be filed with the Coal Mine Safety District Manager and shall contain the following information:
(a) The name and address of the mine operator;
(b) The name and location of the mine;
(c) The thickness of the coal seam in each working place in the mine for which a waiver is requested; and
(d) Other physical restrictions in the mine (for example, poor roof conditions, excessive water, timbering, etc.).
If a sanitary toilet cannot be installed within 500 feet of a working place because of physical conditions other than the thickness of the coal seam, the operator shall also include a short statement specifying areas in the mine which could be considered possible alternative sites for installation of such facilities.§ 75.1712-9 - Issuance of waivers.
Following the receipt of an application submitted in accordance with the provisions of § 75.1712-8, the Coal Mine Safety District Manager shall, if he determines that the operator cannot meet the location requirements of § 75.1712-6 with respect to any or all of the working places in the mine because of the coal seam thickness or because of other physical restriction, issue a waiver of the requirements of this section and designate an alternative site for installation of such facilities. The waiver issued shall specify each working place to which it shall apply, set forth the reasons for such waiver, and the reasons for designation of the alternative site.
§ 75.1712-10 - Underground sanitary facilities; maintenance.
Sanitary toilets shall be regularly maintained in a clean and sanitary condition. Holding tanks shall be serviced and cleaned when full and in no case less than once each week by draining or pumping or by removing them to the surface for cleaning or recharging. Transfer tanks and transfer equipment used underground shall be equipped with suitable fittings to permit complete drainage of holding tanks without spillage and allow for the sanitary transportation of wastes to the surface. Waste shall be disposed of on the surface in accordance with State and local laws and regulations.
§ 75.1713 - Emergency medical assistance; first-aid.
Each operator shall make arrangements in advance for obtaining emergency medical assistance and transportation for injured persons. Emergency communications shall be provided to the nearest point of assistance. Selected agents of the operator shall be trained in first-aid and first-aid training shall be made available to all miners. Each coal mine shall have an adequate supply of first-aid equipment located on the surface, at the bottom of shafts and slopes, and at other strategic locations near the working faces. In fulfilling each of the requirements of this section, the operator shall meet at least minimum requirements prescribed by the Secretary of Health and Human Services.
§ 75.1713-1 - Arrangements for emergency medical assistance and transportation for injured persons; agreements; reporting requirements; posting requirements.
(a) Each operator of an underground coal mine shall make arrangements with a licensed physician, medical service, medical clinic, or hospital to provide 24-hour emergency medical assistance for any person injured at the mine.
(b) Each operator of an underground coal mine shall make arrangements with an ambulance service, or otherwise provide, for 24-hour emergency transportation for any person injured at the mine.
(c) Each operator shall, on or before December 30, 1970, report to the District Manager for the district in which the mine is located the name, title and address of the physician, medical service, medical clinic, hospital or ambulance service with whom arrangements have been made, or otherwise provided, in accordance with the provisions of paragraphs (a) and (b) of this § 75.1713-1.
(d) Each operator shall, within 10 days after any change of the arrangements required to be reported under the provisions of this § 75.1713-1, report such changes to the District Manager. If such changes involve a substitution of persons, the operator shall provide the name, title, and address of the person substituted together with the name and address of the medical service, medical clinic, hospital, or ambulance service with which such person or persons are associated.
(e) Each operator shall, immediately after making an arrangement required under the provisions of paragraphs (a) and (b) of this § 75.1713-1, or immediately after any change of such arrangement, post at appropriate places at the mine the names, titles, addresses, and telephone numbers of all persons or services currently available under such arrangements to provide medical assistance and transportation at the mine.
§ 75.1713-2 - Emergency communications; requirements.
(a) Each operator of an underground coal mine shall establish and maintain a communication system from the mine to the nearest point of medical assistance for use in an emergency.
(b) The emergency communication system required to be maintained under paragraph (a) of this § 75.1713-2 may be established by telephone or radio transmission or by any other means of prompt communication to any facility (for example, the local sheriff, the State highway patrol, or local hospital) which has available the means of communication with the person or persons providing emergency medical assistance or transportation in accordance with the provisions of § 75.1713-1.
§ 75.1713-3 - First-Aid training; supervisory employees.
The mine operator shall conduct first-aid training courses for selected supervisory employees at the mine. Within 60 days after the selection of a new supervisory employee to be so trained, the mine operator shall certify by signature and date the name of the employee and date on which the employee satisfactorily completed the first-aid training course. The certification shall be kept at the mine and made available on request to an authorized representative of the Secretary.
§ 75.1713-4 - First-aid training program; availability of instruction to all miners.
On or before June 30, 1971, each operator of an underground coal mine shall make available to all miners employed in the mine a course of instruction in first-aid conducted by the operator or under the auspices of the operator, and such a course of instruction shall be made available to newly employed miners within 6 months after the date of employment.
§ 75.1713-5 - First-aid training program; retraining of supervisory employees; availability to all miners.
Beginning January 1, 1971, each operator of an underground coal mine shall conduct refresher first-aid training courses each calendar year for all selected supervisory employees, and make available refresher first-aid training courses to all miners employed in the mine.
§ 75.1713-6 - First-aid training program; minimum requirements.
(a) All first-aid training programs required under the provisions of §§ 75.1713-3 and 75.1713-4 shall include 10 class hours of training in a course of instruction similar to that outlined in “First Aid, A Bureau of Mines Instruction Manual.”
(b) Refresher first-aid training programs required under the provisions of § 75.1713-5 shall include five class hours of refresher training in a course of instruction similar to that outlined in “First Aid, A Bureau of Mines Instruction Manual.”
§ 75.1713-7 - First-aid equipment; location; minimum requirements.
(a) Each operator of an underground coal mine shall maintain a supply of the first-aid equipment set forth in paragraph (b) of this § 75.1713-7 at each of the following locations:
(1) At the mine dispatcher's office or other appropriate work area on the surface in close proximity to the mine entry;
(2) At the bottom of each regularly traveled slope or shaft; however, where the bottom of such slope or shaft is not more than 1,000 feet from the surface, such first-aid supplies may be maintained on the surface at the entrance to the mine; and
(3) At a point in each working section not more than 500 feet outby the active working face or faces.
(b) The first-aid equipment required to be maintained under the provisions of paragraph (a) of this § 75.1713-7 shall include at least the following:
(1) One stretcher;
(2) One broken-back board. (If a splint stretcher combination is used it will satisfy the requirements of both (1) and (2)).
(3) 24 triangular bandages (15 if a splint-stretcher combination is used).
(4) Eight 4-inch bandage compresses;
(5) Eight 2-inch bandage compresses.
(6) Twelve 1-inch adhesive compresses;
(7) One foille;
(8) Two cloth blankets:
(9) One rubber blanket or equivalent substitute.
(10) Two tourniquets;
(11) One 1-ounce bottle of aromatic spirits of ammonia or 1 dozen ammonia ampules.
(12) The necessary complements of arm and leg splints or two each inflatable plastic arm and leg splints.
(c) All first-aid supplies required to be maintained under the provisions of paragraphs (a) and (b) of this § 75.1713-7 shall be stored in suitable, sanitary, dust tight, moisture proof containers and such supplies shall be accessible to the miners.
§ 75.1714 - Availability of approved self-rescue devices; instruction in use and location.
(a) Each operator shall make available to each miner who goes underground, and to visitors authorized to enter the mine by the operator, an approved self-rescue device or devices which is adequate to protect such person for 1 hour or longer.
(b) Before any person authorized by the operator goes underground, the operator shall instruct and train such person in accordance with provisions set forth in 30 CFR part 48.
§ 75.1714-1 - Approved self-rescue devices.
The requirements of § 75.1714 shall be met by making available to each person referred to in that section a self-rescue device or devices, which have been approved by MSHA and NIOSH under 42 CFR part 84, as follows:
(a) A 1-hour SCSR;
(b) A SCSR of not less than 10 minutes and a 1-hour canister; or
(c) Any other self-contained breathing apparatus which provides protection for a period of 1 hour or longer and which is approved for use by MSHA as a self-rescue device when used and maintained as prescribed by MSHA.
§ 75.1714-2 - Self-rescue devices; use and location requirements.
(a) Self-rescue devices shall be used and located as prescribed in paragraphs (b) through (f) of this section.
(b) Except as provided in paragraph (c), (d), (e), or (f) of this section, self-rescue devices shall be worn or carried at all times by each person when underground.
(c) Where the wearing or carrying of the self-rescue device is hazardous to the person, it shall be placed in a readily accessible location no greater than 25 feet from such person.
(d) Where a person works on or around equipment, the self-rescue device may be placed in a readily accessible location on such equipment.
(e) A mine operator may apply to the District Manager under § 75.1502 for permission to place the SCSR more than 25 feet away.
(1) The District Manager shall consider the following factors in deciding whether to permit an operator to place a SCSR more than 25 feet from a miner:
(i) Distance from affected sections to surface,
(ii) Pitch of seam in affected sections,
(iii) Height of coal seam in affected sections,
(iv) Location of escapeways,
(v) Proposed location of SCSRs,
(vi) Type of work performed by affected miners,
(vii) Degree of risk to which affected miners are exposed,
(viii) Potential for breaking into oxygen deficient atmospheres,
(ix) Type of risk to which affected miners are exposed,
(x) Accident history of mine, and
(xi) Other matters bearing upon the safety of miners.
(2) Such application shall not be approved by the District Manager unless it provides that, while underground, all miners whose SCSR is more than 25 feet away shall have a FSR approved by MSHA and NIOSH under 42 CFR part 84 sufficient to enable each miner to get to a SCSR.
(3) An operator may not obtain permission under paragraph (e) of this section to place SCSRs more than 25 feet away from miners on trips into and out of the mine.
(f) If an SCSR is not carried out of the mine at the end of a miner's shift, the place of storage shall be approved by the District Manager. A sign made of reflective material with the word “SCSRs” or “SELF-RESCUERS” shall be conspicuously posted at each SCSR storage location. Direction signs made of a reflective material shall be posted leading to each storage location.
(g) Where devices of not less than 10 minutes and 1 hour are made available in accordance with § 75.1714-1(b), such devices shall be used and located as follows:
(1) Except as provided in paragraphs (c) and (d) of this section, the device of not less than 10 minutes shall be worn or carried at all times by each person when underground, and
(2) The one-hour canister shall be available at all times to all persons when underground in accordance with a plan submitted by the mine operator and approved by the District Manager. When the one-hour canister is placed in a storage location, a sign made of a reflective material with the word “SCSRs” or “SELF-RESCUERS” shall be conspicuously posted at each storage location. Direction signs made of a reflective material shall be posted leading to each storage location.
§ 75.1714-3 - Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.
(a) Each operator shall provide for proper inspection, testing, maintenance, and repair of self-rescue devices by a person trained to perform such functions.
(b) After each time a self-rescue device is worn or carried by a person, the device shall be inspected for damage and for the integrity of its seal by a person trained to perform this function. Self-rescue devices with broken seals or which are damaged so that the device will not function properly shall be removed from service.
(c) All FSRs approved by MSHA and NIOSH under 42 CFR part 84, except devices using vacuum containers as the only method of sealing, shall be tested at intervals not exceeding 90 days by weighing each device on a scale or balance accurate to within + 1 gram. A device that weighs more than 10 grams over its original weight shall be removed from service.
(d) All SCSRs approved by MSHA and NIOSH under 42 CFR part 84 shall be tested in accordance with instructions approved by MSHA and NIOSH. Any device which does not meet the specified test requirements shall be removed from service.
(e) At the completion of each test required by paragraphs (c) and (d) of this section the person making the tests shall certify by signature and date that the tests were done. This person shall make a record of all corrective action taken. Certifications and records shall be kept at the mine and made available on request to an authorized representative of the Secretary.
(f) Self-rescue devices removed from service shall be repaired for return to service only by a person trained to perform such work and only in accordance with the manufacturer's instructions.
§ 75.1714-4 - Additional self-contained self-rescuers (SCSRs).
(a) Additional SCSRs in work places. In addition to the requirements in §§ 75.1714, 75.1714-1, 75.1714-2, and 75.1714-3 of this part, the mine operator shall provide the following:
(1) At least one additional SCSR, which provides protection for a period of one hour or longer, for each person at a fixed underground work location.
(2) Additional SCSRs along the normal travel routes for pumpers, examiners, and other persons who do not have a fixed work location to be stored at a distance an average miner could walk in 30 minutes. The SCSR storage locations shall be determined by using one of the methods found under paragraph (c)(2) of this section.
(b) Additional SCSRs on mantrips. If a mantrip or mobile equipment is used to enter or exit the mine, at least one additional SCSR, which provides protection for a period of one hour or longer, shall be available for each person who uses such transportation from portal to portal.
(c) Additional SCSRs in escapeways. When each person underground cannot safely evacuate the mine within 30 minutes, the mine operator shall provide additional SCSRs stored in each required escapeway.
(1) Each storage location shall contain at least one SCSR, which provides protection for a period of one hour or longer, for every person who will be inby that location.
(2) Storage locations shall be spaced along each escapeway at 30-minute travel distances no greater than the distances determined by—
(i) Calculating the distance an average miner walks in 30 minutes by using the time necessary for each miner in a sample of typical miners to walk a typical length of each escapeway; or
(ii) Using the SCSR storage location spacing specified in the following table, except for escapeways with grades over 5 percent.
Average entry height | Maximum distance
between SCSR storage locations (in ft.) | <40 in. (Crawl) | 2,200 | >40-<50 in. (Duck Walk) | 3,300 | >50-<65 in. (Walk Head Bent) | 4,400 | >65 in. (Walk Erect) | 5,700 |
---|
(d) Additional SCSRs in hardened rooms. As an alternative to providing SCSR storage locations in each escapeway, the mine operator may store SCSRs in a hardened room located between adjacent escapeways.
(1) The hardened room shall be designed and constructed to the same explosion force criteria as seals.
(2) The hardened room shall include a means to provide independent, positive pressure ventilation from the surface during an emergency.
(3) The District Manager shall approve the design and construction of hardened rooms in the ventilation plan.
(4) These SCSR storage locations shall be spaced in accordance with paragraph (c) of this section.
(e) Storage location accessibility. All SCSRs required under this section shall be stored according to the manufacturers' instructions, in conspicuous locations readily accessible by each person in the mine.
(f) Storage location signs. A sign made of reflective material with the words “SCSRs” or “SELF-RESCUERS” shall be conspicuously posted at each storage location. Direction signs made of a reflective material shall be posted leading to each storage location.
§ 75.1714-5 - Map locations of self-contained self-rescuers (SCSR).
The mine operator shall indicate the locations of all stored SCSRs on the mine maps required by §§ 75.1200 and 75.1505 of this part.
§ 75.1714-6 - Emergency tethers.
At least one tether, which is a durable rope or equivalent material designed to permit members of a mine crew to link together while evacuating the mine during an emergency, shall be provided and stored with the additional SCSRs on the fixed work location and on the mobile equipment required in §§ 75.1714-4(a)(1) and (b) of this part.
§ 75.1714-7 - Multi-gas detectors.
(a) Availability. A mine operator shall provide an MSHA-approved, handheld, multi-gas detector that can measure methane, oxygen, and carbon monoxide to each group of underground miners and to each person who works alone, such as pumpers, examiners, and outby miners.
(b) Qualified person. At least one person in each group of underground miners shall be a qualified person under § 75.150 of this part and each person who works alone shall be trained to use the multi-gas detector.
(c) Maintenance and calibration. Multi-gas detectors shall be maintained and calibrated as specified in § 75.320 of this part.
§ 75.1714-8 - Reporting SCSR inventory and malfunctions; retention of SCSRs.
(a) SCSR inventory. A mine operator shall submit to MSHA a complete inventory of all SCSRs at each mine. New mines shall submit the inventory within 3 months of beginning operation.
(1) The inventory shall include—
(i) Mine name, MSHA mine ID number, and mine location; and
(ii) For each SCSR unit, the manufacturer, the model type, the date of manufacture, and the serial number.
(2) In the event that a change in the inventory occurs, a mine operator shall report the change to MSHA within the quarter that the change occurs (Jan-Mar, Apr-Jun, Jul-Sep, Oct-Dec).
(b) Reporting SCSR problems. A mine operator shall report to MSHA any defect, performance problem, or malfunction with the use of an SCSR. The report shall include a detailed description of the problem and, for each SCSR involved, the information required by paragraph (a)(1) of this section.
(c) Retention of problem SCSRs. The mine operator shall preserve and retain each SCSR reported under paragraph (b) of this section for 60 days after reporting the problem to MSHA.
§ 75.1715 - Identification check system.
Each operator of a coal mine shall establish a check-in and check-out system which will provide positive identification of every person underground, and will provide an accurate record of the persons in the mine kept on the surface in a place chosen to minimize the danger of destruction by fire or other hazard. Such record shall bear a number identical to an identification check that is securely fastened to the lamp belt worn by the person underground. The identification check shall be made of a rust resistant metal of not less than 16 gauge.
§ 75.1716 - Operations under water.
Whenever an operator mines coal from a coal mine opened after March 30, 1970, or from any new working section of a mine opened prior to such date, in a manner that requires the construction, operation, and maintenance of tunnels under any river, stream, lake, or other body of water, that is, in the judgment of the Secretary, sufficiently large to constitute a hazard to miners, such operator shall obtain a permit from the Secretary which shall include such terms and conditions as he deems appropriate to protect the safety of miners working or passing through such tunnels from caveins and other hazards. Such permits shall require, in accordance with a plan to be approved by the Secretary, that a safety zone be established beneath and adjacent to such body of water. No plan shall be approved unless there is a minimum of cover to be determined by the Secretary, based on test holes drilled by the operator in a manner to be prescribed by the Secretary. No such permit shall be required in the case of any new working section of a mine which is located under any water resource reservoir being constructed by a Federal agency on December 30, 1969, the operator of which is required by such agency to operate in a manner that protects the safety of miners working in such section from cave-ins and other hazards.
§ 75.1716-1 - Operations under water; notification by operator.
An operator planning to mine coal from coal mines opened after March 30, 1970, or from working sections in mines opened prior to such date, and in such manner that mining operations will be conducted, or tunnels constructed, under any river, stream, lake, or other body of water, shall give notice to the Coal Mine Safety District Manager in the district in which the mine is located prior to the commencement of such mining operations.
§ 75.1716-2 - Permit required.
If in the judgment of the Coal Mine Safety District Manager the proposed mining operations referred to in § 75.1716-1 constitute a hazard to miners, he shall promptly so notify the operator that a permit is required.
§ 75.1716-3 - Applications for permits.
An application for a permit required under this section shall be filed with the Coal Mine Safety District Manager and shall contain the following general information:
(a) Name and address of the company.
(b) Name and address of the mine.
(c) Projected mining and ground support plans.
(d) A mine map showing the locations of the river, stream, lake, or other body of water and its relation to the location of all working places.
(e) A profile map showing the type of strata and the distance in elevation between the coal bed and the river, stream, lake or other body of water involved. The type of strata shall be determined by core test drill holes as prescribed by the Coal Mine Safety District Manager.
§ 75.1716-4 - Issuance of permits.
If the Coal Mine Safety District Manager determines that the proposed mining operations under water can be safely conducted, he shall issue a permit for the conduct of such operations under such conditions as he deems necessary to protect the safety of miners engaged in those operations.
§ 75.1717 - Exemptions.
No notice under § 75.1716-1 and no permit under § 75.1716-2 shall be required in the case of any new working section of a mine which is located under any water resource reservoir being constructed by a Federal agency as of December 30, 1969, and where the operator is required by such agency to operate in a manner that adequately protects the safety of miners.
§ 75.1718 - Drinking water.
An adequate supply of potable water shall be provided for drinking purposes in the active workings of the mine, and such water shall be carried, stored, and otherwise protected in sanitary containers.
§ 75.1718-1 - Drinking water; quality.
(a) Potable water provided in accordance with the provisions of § 75.1718 shall meet the applicable minimum health requirements for drinking water established by the State or community in which the mine is located.
(b) Where no state or local health requirements apply to drinking water or where no state or local minimum health requirements exist, drinking water provided in accordance with the provisions of § 75.1718 shall contain a minimum of 0.2 milligrams of free chlorine per liter of water.
§ 75.1719 - Illumination; purpose and scope of §through 75.1719-4; time for compliance.
(a) Section 317(e) of the Act (30 U.S.C. 877(e)) directs and authorizes the Secretary to propose and promulgate standards under which all working places in a mine shall be illuminated by permissible lighting while persons are working in such places §§ 75.1719 through 75.1719-4 prescribe the requirements for illumination of working places in underground coal mines while persons are working in such places and while self-propelled mining equipment is operated in the working place.
(b) Mine operators shall comply with §§ 75.1719 through 75.1719-4 not later than July 1, 1978.
§ 75.1719-1 - Illumination in working places.
(a) Each operator of an underground coal mine shall provide each working place in the mine with lighting as prescribed in §§ 75.1719-1 and 75.1719-2 while self-propelled mining equipment is operated in the working place.
(b) Self-propelled mining equipment; definition. For the purposes of §§ 75.1719 through 75.1719-4, “self-propelled mining equipment” means equipment which possesses the capability of moving itself or its associated components from one location to another by electric, hydraulic, pneumatic, or mechanical power supplied by a source located on the machine or transmitted to the machine by cables, ropes, or chains.
(c) The lighting prescribed in this section shall be in addition to that provided by personal cap lamps.
(d) The luminous intensity (surface brightness) of surfaces that are in a miner's normal field of vision of areas in working places that are required to be lighted shall be not less than 0.06 footlamberts when measured in accordance with § 75.1719-3.
(e) When self-propelled mining equipment specified in paragraphs (e)(1) through (e)(6) of this section is operated in a working place, the areas within a miner's normal field of vision which shall be illuminated in the working place shall be as prescribed in paragraphs (e)(1) through (e)(6) of this section.
(1) Continuous miners and coal-loading equipment. In working places in which continuous miners and coal-loading equipment are operated, the areas which shall be illuminated shall be as follows:
(i) The face, and
(ii) The ribs, roof, floor, and exposed surface of mining equipment, which are between the face and the inby end of the shuttle car or other conveying equipment while in position to receive material.
(2) Self-loading haulage equipment used as a loading machine. In working places in which self-loading haulage equipment is operated to load material, the areas which shall be illuminated shall be as follows:
(i) The face, and
(ii) The ribs, roof, floor, and exposed surfaces of mining equipment, which are between the face and a point 5 feet outby the machine.
(3) Cutting and drilling equipment. In working places in which cutting or drilling equipment is operated, the areas which shall be illuminated shall be as follows:
(i) The ribs, roof, floor, and exposed surfaces of mining equipment, which are between the face and a point 5 feet outby the machine.
(4) Shortwall and longwall mining equipment. In working places in which shortwall or longwall mining equipment is operated, the areas which shall be illuminated shall be as follows:
(i) The area for the length of the self-advancing roof support system and which is between the gob-side of the travelway and the side of the block of coal from which coal is being extracted, and
(ii) The control station, and the head piece and tail piece of the face conveyor, and
(iii) The roof and floor for a distance of 5 feet horizontally from the control station, head piece and tail piece.
(5) Roof bolting equipment. In working places in which roof bolting equipment is operated, the areas which shall be illuminated shall be as follows:
(i) Where the distance from the floor, to the roof is 5 feet, or less: the face, ribs, roof, floor, and exposed surfaces of mining equipment, which are within an area the perimeter of which is a distance of 5 feet from the machine, when measured parallel to the floor.
(ii) Where the distance from the floor to the roof is more than 5 feet: the face, ribs, roof, floor, and exposed surfaces of mining equipment, which are within an area the perimeter of which from the front and sides of the machine is a distance equal to the distance from the floor to the roof and from the rear of the machine a distance of 5 feet, when measured parallel to the floor.
(6) Other self-propelled equipment. Unless the entire working place is illuminated by stationary lighting equipment, in working places in which self-propelled equipment is operated, other than equipment specified in paragraphs (e)(1) through (e)(5) of this section, illumination shall be provided as follows:
(i) Luminaires shall be installed on each machine operated in the working place which shall illuminate a face or rib coal surface which is within 10 feet of the front and the rear of the machine to a luminous intensity of not less than 0.06 footlamberts, and
(ii) The height and width of the area of the coal surface which shall be illuminated shall equal the height and width, respectively, of the machine on which the luminaires are installed, and
(iii) The luminaires in the direction of travel shall be operated at all times the equipment is being trammed in the working place.
(f) The Administrator, Coal Mine Health and Safety, MSHA, may specify other areas in a working place to be illuminated for the protection of miners while self-propelled mining equipment is being operated in the working place.
(g) Surface brightness of floor, roof, coal and machine surfaces in the normal visual field of a miner shall not vary more than 50 percent between adjacent fields of similar surface reflectance, and the maximum surface brightness of such surface shall not exceed 120 footlamberts when measured in accordance with § 75.1719-3.
§ 75.1719-2 - Lighting fixtures; requirements.
(a) Lighting fixtures shall be permissible.
(b) Lighting fixtures may be installed on self-propelled machines or may be stationary lighting fixtures.
(c)(1) Electrically operated lighting fixtures shall be energized by direct current, or by sinusoidal full wave alternating current not less than 50 cycles per second (100 pulses per second), or by an equivalent power source that causes no greater flicker.
(2) Alternating current circuits supplying power to stationary lighting fixtures shall contain conductors energized at voltages not greater than 70 volts to ground. Alternating current circuits, energized at 100 volts or more and used to supply power to stationary lighting fixtures, shall originate at a transformer having a center or neutral tap grounded to earth through a proper resistor, which shall be designed to limit fault current to not more than 5 amperes. A grounding circuit in accordance with § 75.701-4 shall originate at the grounded terminal of the grounding resistor and extend along with the power conductors and serve as a grounding conductor for the frames of all equipment receiving power from the circuit. The ground fault current rating of grounding resistors shall meet the “extended time rating” set forth in the Institute of Electrical and Electronics Engineers, Inc. Standard No. 32 (IEEE Std. 32-1972) which is hereby incorporated by reference and made a part hereof. The incorporated publication is available for examination at each MSHA Coal Mine Safety and Health district office, and may be obtained from the Institute of Electrical and Electronics Engineers, Inc., Publications Office, 10662 Los Vaqueros Circle, P.O. Box 3014 Los Alamitos, CA 90720-1264 Telephone: 800-272-6657 (toll free); http://www.ieee.org.
(3) Machine-mounted lighting fixtures shall be electrically grounded to the machine by a separate grounding conductor in compliance with § 75.701-4.
(d) Direct current circuits in excess of a nominal voltage of 300 volts shall not be used to supply power to stationary light fixtures.
(e) Cables conducting power to stationary lighting fixtures from both alternating and direct current power sources, other than intrinsically safe devices, shall be considered trailing cables, and shall meet the requirements of Subpart G of this part. In addition, such cables shall be protected against overloads and short circuits by a suitable circuit breaker or other device approved by the Secretary. Circuit breakers or other device approved by the Secretary protecting trailing cables receiving power from resistance grounded circuits shall be equipped with a ground trip arrangement which shall be designed to deenergize the circuit at not more than 50% of the available fault current.
(f) Before shunts are removed from blasting caps, lighting fixtures and associated cables located in the same working place shall be deenergized. Furthermore, lighting fixtures shall be removed out of the line of blast and not less than 50 feet from the blasting operation unless otherwise protected against flying debris.
(g) Lighting fixtures shall be designed and installed to minimize discomfort glare.
§ 75.1719-3 - Methods of measurement; light measuring instruments.
(a) Compliance with § 75.1719-1(d) shall be determined by MSHA by measuring luminous intensity (surface brightness).
(b) In measuring luminous intensity the following procedures shall be used:
(1) In areas of working places specified in §§ 75.1719.1(e)(1) through 75.1719-1(e)(3) luminous intensity measurements of the face, ribs, roof, floor, and exposed surfaces of mining equipment, shall be made with the machine idle and located in the approximate center of the working place with the cutting, loading, or drilling head toward the face and not more than 3 feet from the face.
(2) In areas of working places specified in § 75.1719-1(e)(4) luminous intensity measurements may be made at any time longwall or shortwall mining equipment is operated except that when measurements are made in the vicinity of shearers, plows, or continuous miners, the equipment shall be idle while measurements are being made.
(3) In areas of working places specified in § 75.1719-1(e)(5) luminous intensity measurements of the face, ribs, roof, floor, and exposed surfaces of mining equipment, shall be made with the machine idle and located in the approximate center of the working place with the drilling head toward the face and a distance from the face of 5 feet, or the distance from the floor to the roof, whichever is applicable. When the machine is located in the center of the working place and the surfaces of the ribs to be illuminated are not within the perimeter of the area determined in accordance with § 75.1719-1(e)(5), the machine shall be positioned the applicable distance from the face and each rib and luminous intensity measurements made for each rib, provided, however, that luminous intensity measurements may be made of the face, roof, floor, and exposed surfaces of mining equipment with the machine so located without locating the machine in the center of the working place.
(4) In areas of working places specified in § 75.1719-1(e)(6), luminous intensity measurements of a coal surface shall be made with the machine idle and located in the approximate center of the working place with the appropriate end toward the face and not less than 9 feet nor more than 10 feet from the face.
(5) The area of surfaces to be measured shall be divided into round or square fields having an area of not less than 3 nor more than 5 square feet as illustrated by the following figure:
(6) Measurements shall be taken with the photometer held approximately perpendicular to the surface being measured and a sufficient distance from the surface to allow the light sensing element in the instrument to receive reflected light from a field of not less than 3 nor more than 5 square feet. The luminous intensity of each such field shall be not less than 0.06 footlambert.
(7) In areas of working places where clearances are restricted to the extent that the photometer cannot be held a sufficient distance from the surface to allow the light sensing element in the instrument to receive reflected light from a field having an area of at least 3 square feet, luminous intensity shall be considered as the average of four uniformly spaced readings taken at the corners and within a square field having an area of approximately 4 square feet. In such instances, the area of each of the individual readings shall not exceed 100 square inches. The average of the four readings shall be not less than 0.06 footlambert. The method of measurement is illustrated by the following figure:
(8) Measurements shall not be made where shadows are cast by roof control posts, ventilation equipment, or other obstructions necessary to insure safe mining conditions.
(9) Where machine-mounted light fixtures are used on equipment, except self advancing roof support systems, measurements shall not be made of surfaces on or within 1 foot of a self-propelled machine.
(c) For the purpose of making illumination measurements, an authorized representative of the Secretary may require the installation of temporary roof supports or the removal of the equipment to a similar working place in which permanent roof supports have been installed.
(d) Light measuring instruments shall be properly calibrated and maintained. Instruments shall be calibrated against standards traceable to the National Institute of Standards and Technology (Formerly the National Bureau of Standards) and color corrected to the Commission Internationale de l'Eclairage (CIE) Spectral Luminous Curve. The CIE Spectral Luminous Curve is as follows:
§ 75.1719-4 - Mining machines, cap lamps; requirements.
(a) Paint used on exterior surfaces of mining machines shall have a minimum reflectance of 30 percent, except cab interiors and other surfaces which might adversely affect visibility.
(b) When stationary light fixtures are used, red reflectors mounted in protective frames or reflecting tape shall be installed on each end of mining machines, except that continuous mining machines, loaders, and cutters need only have such reflectors or tape on the outby end. Reflectors or reflecting tape shall have an area of not less than 10 square inches.
(c) Each person who goes underground shall be required to wear an approved personal cap lamp or an equivalent portable light.
(d) Each person who goes underground shall be required to wear a hard hat or hard cap which shall have a minimum of 6 square inches of reflecting tape or equivalent paint or material on each side and back.
§ 75.1720 - Protective clothing; requirements.
On and after the effective date of this § 75.1720 each miner regularly employed in the active workings of an underground coal mine shall be required to wear the following protective clothing and devices:
(a) Protective clothing or equipment and face-shields or goggles when welding, cutting, or working with molten metal or when other hazards to the eyes exist from flying particles.
(b) Suitable protective clothing to cover those parts of the body exposed to injury when handling corrosive or toxic substances or other materials which might cause injury to the skin.
(c) Protective gloves when handling materials or performing work which might cause injury to the hands; however, gloves shall not be worn where they would create a greater hazard by becoming entangled in the moving parts of equipment.
(d) A suitable hard hat or hard cap. If a hard hat or hard cap is painted, nonmetallic based paint shall be used.
(e) Suitable protective footwear.
§ 75.1720-1 - Distinctively colored hard hats, or hard caps; identification for newly employed, inexperienced miners.
Hard hats or hard caps distinctively different in color from those worn by experienced miners shall be worn by each newly employed, inexperienced miner for at least one year from the date of his initial employment as a miner or until he has been qualified or certified as a miner by the State in which he is employed.
§ 75.1721 - Opening of new underground coal mines, or reopening and reactivating of abandoned or deactivated coal mines, notification by the operator; requirements.
(a) Each operator of a new underground coal mine, and a mine which has been abandoned or deactivated and is to be reopened or reactivated, shall prior to opening, reopening or reactivating the mine notify the Coal Mine Health and Safety District Manager for the district in which the mine is located of the approximate date of the proposed or actual opening of such mine. Thereafter, and as soon as practicable, the operator of such mine shall submit all preliminary plans in accordance with paragraphs (b) and (c) of this section to the District Manager and the operator shall not develop any part of the coalbed in such mine unless and until all preliminary plans have been approved.
(b) The preliminary plans required to be submitted by the operator to the District Manager shall be in writing and shall contain the following:
(1) The name and location of the proposed mine and the Mine Safety and Health Administration mine identification number, if known;
(2) The name and address of the mine operator(s);
(3) The name and address of the principal official designated by the operator as the person who is in charge of health and safety at the mine;
(4) The identification and approximate height of the coalbed to be developed;
(5) The system of mining to be employed;
(6) A proposed roof control plan containing the information specified in § 75.220.
(7) A proposed mine ventilation plan containing the information specified in §§ 75.371 and 75.372;
(8) A proposed plan for sealing worked-out areas containing the information specified in §§ 75.371 and 75.372.
(9) A proposed program for searching miners for smoking materials in accordance with the provisions of § 75.1702; and,
(10) A proposed plan for emergency medical assistance and emergency communication in accordance with the provisions of §§ 75.1713-1 and 75.1713-2.
(c) The preliminary plans required to be submitted by the operator to the District Manager shall be in writing and shall contain the following:
(1) The proposed training plan containing the information specified in §§ 48.3 and 48.23 of this chapter, and
(2) A proposed plan for training and retraining certified and qualified persons containing the information specified in § 75.160-1.
§ 75.1722 - Mechanical equipment guards.
(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.
(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.
(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.
§ 75.1723 - Stationary grinding machines; protective devices.
(a) Stationary grinding machines other than special bit grinders shall be equipped with:
(1) Peripheral hoods (less than 90° throat openings) capable of withstanding the force of a bursting wheel.
(2) Adjustable tool rests set as close as practical to the wheel.
(3) Safety washers.
(b) Grinding wheels shall be operated within the specifications of the manufacturer of the wheel.
(c) Face shields or goggles, in good condition, shall be worn when operating a grinding wheel.
§ 75.1724 - Hand-held power tools; safety devices.
Hand-held power tools shall be equipped with controls requiring constant hand or finger pressure to operate the tools or shall be equipped with friction or other equivalent safety devices.
§ 75.1725 - Machinery and equipment; operation and maintenance.
(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.
(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.
(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.
(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.
§ 75.1726 - Performing work from a raised position; safeguards.
(a) Men shall not work on or from a piece of mobile equipment in a raised position until it has been blocked in place securely. This does not preclude the use of equipment specifically designed as elevated mobile work platforms.
(b) No work shall be performed under machinery or equipment that has been raised until such machinery or equipment has been securely blocked in position.
§ 75.1727 - Drive belts.
(a) Drive belts shall not be shifted while in motion unless the machines are provided with mechanical shifters.
(b) Belt dressing shall not be applied while belts are in motion except where it can be applied without endangering a person.
§ 75.1728 - Power-driven pulleys.
(a) Belts, chains, and ropes shall not be guided onto power-driven moving pulleys, sprockets, or drums with the hands except on slow-moving equipment especially designed for hand feeding.
(b) Pulleys of conveyors shall not be cleaned manually while the conveyor is in motion.
(c) Coal spilled beneath belt conveyor drives or tail pieces shall not be removed while the conveyor is in motion, except where such coal can be removed without endangering persons.
§ 75.1729 - Welding operations.
Welding operations shall be shielded and the area shall be well ventilated.
§ 75.1730 - Compressed air; general; compressed air systems.
(a) All pressure vessels shall be constructed, installed, and maintained in accordance with the standards and specifications of Section VIII “Unfired Pressure Vessels,” of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (1971), which is hereby incorporated by reference and made a part hereof. This document may be purchased from the American Society of Mechanical Engineers, 22 Law Drive, P.O. Box 2900, Fairfield, New Jersey 07007, Phone: 800-843-2763 (toll free); http://www.asme.org; and it is available for examination in every MSHA Coal Mine Safety and Health district office.
(b) Compressors and compressed-air receivers shall be equipped with automatic pressure-relief valves, pressure gages, and drain valves.
(c) Repairs involving the pressure system of compressors, receivers, or compressed-air-powered equipment shall not be attempted until the pressure has been relieved from that part of the system to be repaired.
(d) At no time shall compressed air be directed toward a person. When compressed air is used, all necessary precautions shall be taken to protect persons from injury.
(e) Safety chains, suitable locking devices, or automatic cut-off valves shall be used at connections to machines of high-pressure hose lines of three-fourths of an inch inside diameter or larger, and between high-pressure hose lines of three-fourths of an inch inside diameter or larger, where a connection failure would create a hazard. For purposes of this paragraph, high-pressure means pressure of 100 p.s.i. or more.
§ 75.1731 - Maintenance of belt conveyors and belt conveyor entries.
(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.
(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.
(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.
(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.
§ 75.1732 - Proximity detection systems.
Operators must install proximity detection systems on certain mobile machines.
(a) Machines covered. Operators must equip continuous mining machines, except full-face continuous mining machines, with proximity detection systems by the following dates. For proximity detection systems with miner-wearable components, the mine operator must provide a miner-wearable component to be worn by each miner on the working section by the following dates.
(1) Continuous mining machines manufactured after March 16, 2015 must meet the requirements in this section no later than November 16, 2015. These machines must meet the requirements in this section when placed in service with a proximity detection system.
(2) Continuous mining machines manufactured and equipped with a proximity detection system on or before March 16, 2015 must meet the requirements in this section no later than September 16, 2016.
(3) Continuous mining machines manufactured and not equipped with a proximity detection system on or before March 16, 2015 must meet the requirements in this section no later than March 16, 2018. These machines must meet the requirements in this section when placed in service with a proximity detection system.
(b) Requirements for a proximity detection system. A proximity detection system includes machine-mounted components and miner-wearable components. The system must:
(1) Cause a machine, which is tramming from place-to-place or repositioning, to stop before contacting a miner except for a miner who is in the on-board operator's compartment;
(2) Provide an audible and visual warning signal on the miner-wearable component and a visual warning signal on the machine that alert miners before the system causes a machine to stop. These warning signals must be distinguishable from other signals;
(3) Provide a visual signal on the machine that indicates the machine-mounted components are functioning properly;
(4) Prevent movement of the machine if any machine-mounted component of the system is not functioning properly. However, a system with any machine-mounted component that is not functioning properly may allow machine movement if it provides an audible or visual warning signal, distinguishable from other signals, during movement. Such movement is permitted only for purposes of relocating the machine from an unsafe location for repair;
(5) Be installed to prevent interference that adversely affects performance of any electrical system; and
(6) Be installed and maintained in proper operating condition by a person trained in the installation and maintenance of the system.
(c) Proximity detection system checks. Operators must:
(1) Designate a person who must perform a check of machine-mounted components of the proximity detection system to verify that components are intact, that the system is functioning properly, and take action to correct defects—
(i) At the beginning of each shift when the machine is to be used; or
(ii) Immediately prior to the time the machine is to be operated if not in use at the beginning of a shift; or
(iii) Within 1 hour of a shift change if the shift change occurs without an interruption in production.
(2) Check for proper operation of miner-wearable components at the beginning of each shift that the components are to be used and correct defects before the components are used.
(d) Certifications and records. The operator must make and retain certifications and records as follows:
(1) At the completion of the check of machine-mounted components required under paragraph (c)(1) of this section, a certified person under § 75.100 must certify by initials, date, and time that the check was conducted. Defects found as a result of the check, including corrective actions and dates of corrective actions, must be recorded before the end of the shift;
(2) Make a record of the defects found as a result of the check of miner-wearable components required under paragraph (c)(2) of this section, including corrective actions and dates of corrective actions;
(3) Make a record of the persons trained in the installation and maintenance of proximity detection systems required under paragraph (b)(6) of this section;
(4) Maintain records in a secure book or electronically in a secure computer system not susceptible to alteration; and
(5) Retain records for at least one year and make them available for inspection by authorized representatives of the Secretary and representatives of miners.